Superior DRL6542TEN Installation And Operation Instructions Manual page 17

Drl 6000 series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRL6000 Series Direct-Vent Gas Fireplaces
TM
Table 10: Fireplace Framing Dimensions
Model
a
53 3/4
42"
1366
65 3/4
54"
1670
NOTE: Illustration provided for dimensions. Fireplace must be adequately
framed and supported with 2 x 4, or larger building materials.
a. Required frame opening width (1/2 of a = horizontal centerline of
fireplace and vent framing opening)
b. Required frame opening depth with 1/2" (13mm) thick wall finish
material (for other wall finish thicknesses, adjust frame opening depth
and nailing flanges accordingly)
c. Minimum frame opening height (from base of appliance to header)
d. Minimum height from appliance base to vertical centerline of horizontal
termination vent pipe (with 6" [54" models] or 12" [42" models]
straight vent section and 90° elbow off appliance vent collar)
NOTE: The vertical centerline of the horizontal termination vent pipe is NOT the same as
the vertical centerline of the vent frame opening because of firestop/spacer offset.
e. Minimum height from appliance base front to ceiling
f. Mounting platform
NOTE: Mount on a fully supported platform extending full width and depth of unit.
Table 11: Fireplace Framing Specifications—Corner Installation with Horizontal Termination
Model
A
B
53 3/4"
81 1/4"
42"
(1365 mm)
(2063 mm)
65 3/4"
98 5/8"
54"
(1670 mm)
(2505 mm)
NOTE: Back wall of chase/enclosure (including finishing materials) shown.
Table 12: Fireplace Dimensions
9 7/8
(251)
A
B
9 3/8
Top View
(238.1)
Model
A
26 7/8"
42"
(683 mm)
(1366 mm)
9 7/8
(251)
32 1/2"
54"
(826 mm)
(1670 mm)
NOTE: Assemble top standoffs before installing fireplace.
b
c
18 1/2
42
470
1067
18 1/2
46 3/4
470
1184
C
D
57 1/2"
40 5/8"
(1459 mm)
(1032 mm)
70 5/16"
49 3/4"
(1786 mm)
(1264 mm)
9 7/8
(251)
9 3/8
(238.1)
D
Inches
(millimeters)
9 7/8
(251)
18 1/2
(471.2)
Top/Bottom
B
C
Nailing
langes
53 3/4"
32 1/2"
(826 mm)
65 3/4"
36 3/8"
(924 mm)
d
50 3/8
1280
48 1/4
1226
65
(1651)
Note: Illustration provided for dimension information only. Fireplace must be adequately framed and suppo
A = Required frame opening width. (1/2 of A = horizontal centerline of fireplace and vent framing opening.)
B = Required frame opening depth with 1/2" (13mm) thick wall finish material. For other wall finish thicknesses
adjust frame opening depth and nailing flanges accordingly (see "Unit Nailing Flanges" section).
E
C = Min. frame opening height (from base of appliance to header).
D = Min. height from appliance base to vertical centerline of horizontal termination vent pipe (with 6" straigh
22 3/16"
section and 90° elbow off appliance vent collar). (Note: Vertical centerline of horizontal termination vent
(564 mm)
is NOT the same as vertical centerline of vent frame opening. ecause of firestop/spacer offset.
See "Exterior Wall Opening Framing" section.)
28 1/2"
E = Min. height from appliance base (front) to ceiling.
(724 mm)
F = Mounting platform (Note: Mount appliance on fully supported platform extending full width and depth of
Inches
(millimeters)
E
F
C
Front View
Right Side View
D
E
15 3/4"
44 1/8"
(400 mm)
(1121 mm)
19 3/4"
56 1/8"
(502 mm)
(1426 mm)
10-1/2
(267)
e
d
c
b
a
1/2 of A
E
C
D
A
B
Table 13: Viewable Glass
42" models
54" models
18 1/2
(471.2)
Table 14: Surround Dimensions
42" models
Top/Bottom
Nailing
langes
54" models
Table 15: Vent Collar
All models
NOTE: Before installing fireplace,
nailing flanges MUST be adjusted
F
according to finish (cleanface or
surround) and wall finish material
15 11/16"
thickness. This is critical to ensure
(398 mm)
proper fireplace location, especially if
19 5/8"
installing optional surround and bezel.
(498 mm)
Installation
900077-00, 03/2014
12-1/8
(308)
f
inches
(millimeters)
7 (178)
40" W x 10 1/2" H
1016 mm x 267 mm
51" W x 14 3/4" H
1295 mm x 375 mm
55" W x 22 1/4" H
1397 mm x 565 mm
67" W x 26" H
1702 mm x 660 mm
4 1/2" inner x 7 1/2" outer
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl6554ten

Table of Contents