Packaging; Introduction; Installation - Superior DRL6542TEN Installation And Operation Instructions Manual

Drl 6000 series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRL6000 Series Direct-Vent Gas Fireplaces
TM

INSTALLATION

PACKAGING

All models include
The assembled vented gas fireplace heater is packaged with:
Literature Kit (Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels)
Vent restrictor assembly
Baffle (shipped on fireplace floor)
Three (3) Non-combustible fiber boards
Three (3) AAA batteries
Handheld remote control (transmitter)
Remote control receiver (wall switch) assembly with four (4) AA batteries
Required accessories
Firebox liner kit
Floor kit
Glass media kit (required with DESIGNER style floor kits only)
NOTE: Ensure all required accessory kits are available before installing the fireplace.
Optional accessories
Surround kit
Bezel kit
Panel backlighting kit
Power vent kit (Requires Rhapsody power vent adaptor kit)
Gas conversion kit

INTRODUCTION

These vented gas fireplace heaters are sealed combustion, air-circulating gas fireplaces designed for residential,
manufactured home, and commercial applications. Direct-vent appliances operate with the combustion chamber
isolated from the indoor environment. All air for combustion is brought in from the outside, and exhaust gases are
vented through the same direct-vent, coaxial (intake/exhaust) vent system.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or fuel combinations
will degrade the performance of this system, may be dangerous, and may void the warranty.
Electronic fireplaces are designed with an electronic intermittent pilot ignition system. External electrical power is
required to operate these units. In the event of a power outage, four (4) AA batteries (in battery holder) provide
backup power for fireplace operation.
Batteries will operate the gas valve OPEN/CLOSE and pilot ON/OFF functions only. Electrical power (120V AC line
voltage) is required to operate the following components:
Blower
Power vent system
Panel backlighting kit
A remote control system is included with all models and provides remote operation of several fireplace functions
(manual adjustment of the gas valve settings is not possible).
NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected before
use and at least annually by a professional service person. More frequent cleaning may be required due to excessive
lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air
passageways of the fireplace be kept clean.
Remarqué : L'installation et la réparation devrait être confiées à un technicien qualifié. L'appareil devrait faire
l'objet d'une inspection par un technicien professionnel avant d'être utilisé et au moins une fois l'an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité
importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les
conduits de circulation d'air de l'appareil soient tenus propres.
NOTE: Diagrams and illustrations are not necessarily shown to scale.
Installation
900077-00, 03/2014
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl6554ten

Table of Contents