Drl6500 linear direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces
2. Connect the flare fitting on the flex-line to the shutoff valve. Tighten by hand, and then use a pipe wrench to
Figure 32 - Control Compartment
Access the Control Compartment
See Page 54 for instructions on Accessing the Control Compartment.
The control valve has a 3/8" (10 mm) NPT thread inlet port.
Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are
used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and
other openings can be caulked or stuffed with unfaced fiberglass insulation.
All codes require a shutoff valve mounted in the supply line. The orientation of the shutoff valve should face the
front. Figure 33 illustrates two methods for connecting the gas supply. A sediment trap is recommended to prevent
moisture and debris in the gas line from damaging the valve.
Test Factory and Field Connections for Gas Leaks
Never use an open flame to check for leaks.
Turn on gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution.
NOTE: Using a soapy water solution is an effective leak test solution but it is not recommended, because the soap
residue that is left on the pipes/fittings can result in corrosion over time.
1. Light the fireplace (refer to the lighting instructions label in the control compartment or Page 66).
2. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas
3. When the gas lines are tested and leak free, rinse off the leak testing solution.

Optional: Install the Modesty Panel

11.
1. Insert the four (4) hooks on the modesty panel into the four slots on the door flange.
2. Slide the modesty panel to the left until it is fully seated.

Install the wall Switch Receiver

12.
The wall switch receiver for the Total Comfort Control™ remote control system connects directly to the gas valve,
stepper motor, and fan control module with an umbilical cord wiring harness.
1. When wall finish is complete, install the wall switch receiver in the previously installed junction box, and connect
2. Install the receiver cover plate. Ensure the receiver switch is properly aligned with the switch cover

Verify Proper Fireplace Operation

13.
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions (Page 66).
38
tighten completely, 1/4-turn at a time.
Main gas shutoff valve
odor is detected, turn the receiver or remote control to the OFF position. Either tighten or refasten the leaking
connection, and then retest as described above.
the terminal to the connector on the back of the receiver.
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
When purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace will not
require purging.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 33 - Gas Line Connection
1/2 x 3/8" Flare
1/2" x 3/8" Flare
shutoff valve
Shut-Off Valve
Gas
Gas
Stub
stub
WARNING
Installation
900077-00, 07/2015
Flex Line Connector
3/8 NPT x 3/8"
3/8" NPT x 3/8"
Flare Fitting
Flare fitting
Gas
Gas
3/8" Flex tubing
valve
Valve
3/8" Flex Tubing