Superior DRL6542TEN Installation And Operation Instructions Manual

Drl 6000 series direct-vent gas fireplaces

Advertisement

P/N 900077-00 Rev. NC 03/2014
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900077-01.
P900077-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Superior
DRL 6000 Series Direct-Vent Gas Fireplaces
TM
Models
DRL6542TEN
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
DRL6554TEN
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRL6542TEN

  • Page 1 Superior DRL 6000 Series Direct-Vent Gas Fireplaces P/N 900077-00 Rev. NC 03/2014 Models Ce manuel est disponible en francais, simplement DRL6542TEN DRL6554TEN en faire la demande. Numéro de la pièce 900077-01. P900077-00 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2 Innovative Hearth Products General Information Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 3: Table Of Contents

    Innovative Hearth Products General Information Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 4: General Information

    Innovative Hearth Products General Information Superior DRL6000Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 GENERAL INFORMATION IMPORTANT SAFETY INFORMATION L’information de sûreté importante Información importante de seguridad WARNING AVERTISSEMENT ADVERTENCIA Do not operate appliance with the Ne pas utiliser l’appareil si le...
  • Page 5: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 FIREPLACE INSTALLATION, OPERATION, AND MAINTENANCE NOTICES DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION, AND LISTINGS OF THIS UNIT.
  • Page 6 Innovative Hearth Products General Information Superior DRL6000Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 WARNING Clothing or other flammable material should not be placed on or near the appliance. AVERTISSEMENT On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
  • Page 7: Packaging

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels) •...
  • Page 8 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Approved Vent Components These fireplaces are designed, tested and listed for operation and installation with the following vent components only: • Secure Vent Direct-Vent System Components, ® •...
  • Page 9 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 1: Electronic Gas Valve Green Wire (from DFC Wire Harness) Connect GTMS Manifold (OUT) wire harness Test Port Inlet (IN) Test Port Pressure Regulator Tower Orange Wire...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 7: Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exceptions: •...
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Wall Finishes / Surrounds / Mantels Clearances to combustible mantels vary according to mantel depth (Figure 6). Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do NOT allow anything to hang below the top edge of the fireplace door.
  • Page 16: Installation Sequence

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 17 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 10: Fireplace Framing Dimensions Model 53 3/4 18 1/2 50 3/8 42” 10-1/2 1366 1067 1280 (267) 65 3/4 18 1/2 46 3/4 48 1/4 54” 1670...
  • Page 18: Route The Gas Supply Line Into The Fireplace

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Prepare the Fireplace Top Spacers 1. The two (2) 9 3/8” standoff spacers on top of the fireplace cabinet are shipped flat (Figure 8). 2. Bend the standoffs as shown (Figure 8): 3.
  • Page 19 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 CAUTION If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
  • Page 20 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Place the Fireplace in the Framing and Secure 1. Secure the fireplace to the side framing members using the unit’s nailing flanges —one top and bottom on each side of the fireplace front (Figure 14).
  • Page 21 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 15: When to use a vent restrictor Figure 16: Vent restrictor installation, Top vent Base Position 1 Position 2 U-Shaped 60 ft Maximum vertical run Vent Vent...
  • Page 22 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Connecting the vent pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist lock connections ® (Figure 18 and Figure 19). All of the fireplaces covered in this document are fitted with collars having locking inclined channels. The dimpled end of the vent components fit over the fireplace/vent collar to create the positive twist lock connection.
  • Page 23 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 17: Vent Section Length Nominal Section Nominal Section Length Length (in.) (in.) Net Section Length 10.5 22.5 34.5 46.5 Net Section Length (in.) 10.5 22.5 34.5 46.5 (in.)
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (25 mm) from all sides NOTE: Attic insulation shield (96K94) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Page 21 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 26 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape.
  • Page 27 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Vertical Vent Figures/Tables NOTE: If the parameters of your vent run fall outside the parameters described herein, consider installing the Power Vent Kit. NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 28 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 19: Top Vent—Two 90° Elbows Table 20: Top Vent—Three Elbows Vertical Firestop/ Spacer Horizontal Firestop/ Vertical Firestop/ Spacer Spacer  Horizontal Firestop/  Spacer   Maximum total H...
  • Page 29 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 7. Support the vertical run sections—On the vertical run, support the venting system every 8 ft (2.4 m) above the fireplace vent outlet with field provided support straps (Plumber’s tape). Attach the straps to the vent pipe and secure to the framing members with nails or screws (Figure 23).
  • Page 31 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 28: Installing the Horizontal Termination Typical Firestop/Spacer (SV4.5HF) shown Termination on the exterior side of the wall. It Shown may also be installed on the interior side.
  • Page 32 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 21: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6–9 1/4” (152–235 mm) Termination Kit and 6”...
  • Page 33 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 23: Top Vent—Two 90° Elbows Maximum total H Minimum total V Horizontal Horizontal Firestop/ Termination  feet meters feet meters Spacer 0.610 0.305 1.372 0.914 1.829 1.220 2.286...
  • Page 34 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Vertical or Horizontal Venting Using Secure Flex Kits and Components Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5)
  • Page 35: Complete The Field Wiring

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent.
  • Page 36 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 32: Wiring Diagram—Electronic Gas Valves IPI Pilot Flame Sensor Schematic Representation Only Spark Electrode COLOR CODE: B = BLACK Pilot Tube BB = BROWN W/BLACK STRIPE BG = BROWN W/GREEN STRIPE...
  • Page 37: Optional: Wire And Install The Power Vent

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment. This grounding plug provides protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 38: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 2. Connect the flare fitting on the flex-line to the shutoff valve. Tighten by hand, and then use a pipe wrench to tighten completely, 1/4-turn at a time.
  • Page 39: Optional: Install The Backlighting Reflector

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Optional: Install the Backlighting Reflector See the kit literature for more information. Install the Firebox Liners 1. See Page 56 for instructions on Installing the Firebox Liners. Optional: Install the Backlighting Light Assemblies See the kit literature for more information.
  • Page 40 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening. To achieve a warm yellow-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
  • Page 41: Install The Finishing Materials

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Install the Finishing Materials NOTE: To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness of the finished wall. NOTE: See Cold Climate Insulation on Page 10 and Vent Termination Clearances on Page 12.
  • Page 42 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 43: Noncombustible Material with Cleanface Finish— Figure 44: Noncombustible Material with Surround and Bezel— Profile View Profile View * Insulation and combustible * Insulation and combustible Insulation and combustible Insulation and combustible Min.
  • Page 43: Optional: Install The Bezel

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 45: Installing the Surround Figure 46: Noncombustible Material with Surround and Bezel Top Non-Combustible Fiber Board Cut to height of installed Top Spacers. Top Nailing Flange Remove Left...
  • Page 44: Install The Wall Switch Receiver

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Install the Wall Switch Receiver The wall switch receiver for the Total Comfort Control™ remote control system connects directly to the gas valve, stepper motor, and fan control module with an umbilical cord wiring harness.
  • Page 45: Attach The Safety-In-Operation Warnings

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 46: Installation Accessories

    Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 INSTALLATION ACCESSORIES Table 41: Table 27: Listed Secure Vent Components (Note: All Small Terminations are for 42” Models Only!) ® Catalog Number Model Description Catalog Number Model Description...
  • Page 47 Innovative Hearth Products Installation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Table 42: Table 27: Listed Secure Vent Components ® Catalog Number Model Description Catalog Number Model Description Through Wall Shield Kit (to Attic Insulation Shield H5816 shield direct- SV4.5-TWSK10...
  • Page 48: Gas Conversion Kits

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 49 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 50 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 12. Make stepper motor and valve electrical connections. 13. Remove the pilot hood assembly to access the hex pilot orifice (Figure 51). Remove and replace the pilot orifice with the one provided with the kit. Exercise extreme care to prevent damage to or breakage of the igniter assembly.
  • Page 51 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 52 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 53 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 54 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 The fireplace main burner can be turned ON/OFF with the wall switch or remote control. Check the batteries, at least every three (3) months to ensure they are properly charged.
  • Page 55 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 54: Remote Control Transmitter Display Child Safety Lock-Out Transmission Low Battery Alarm Thermostat Room OFF/ON/SMART Temperature Set Point Temp./Level/State Fan Control Flame On Light On Maximum Level...
  • Page 56: Installing Firebox Liners

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Optional Lighting Control Turning OFF the fireplace with the wall switch will NOT turn OFF the lighting (if installed). To turn OFF these functions, use the remote control before turning OFF the fireplace with the wall switch receiver.
  • Page 57: Operation

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Installing and removing the glass door WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. • Remove glass door only when fireplace is OFF and COLD.
  • Page 58 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
  • Page 59: Maintenance

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 60 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 61 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 28: Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By...
  • Page 62: Required Accessory Components

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 REQUIRED ACCESSORY COMPONENTS Firebox Liner Kits Rhapsody Linear Panel Kit: Table 30: Firebox Liner Kits ILLUSION CITYSCAPE Catalog Model Description Used on Nake Black Porcelain H8834 NPK-BLP-RAP42 Nake Black...
  • Page 63: Optional Accessory Components

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 OPTIONAL ACCESSORY COMPONENTS Surround/Bezel Kits Table 33: Surround Kits Catalog No. Model No. Description H8825 CS-BLS-RAP42 Black Satin, 42” models H8414 CS-BLS-RAP54 Black Satin, 54” models Table 34: Bezel Kits Catalog No.
  • Page 64: Lighting Instructions

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
  • Page 65 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 POUR PLUS DE SÉCURITÉ, LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT : Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 66: Troubleshooting

    Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 67 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 REPLACEMENT PARTS Contact an IHP dealer to obtain any of these parts. Contact IHP for the phone number of your nearest IHP dealer. Table 45: Installer Replacement Parts 42”...
  • Page 68 Innovative Hearth Products Operation Superior DRL6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 Figure 59: Replacement Parts Remote Power 120V SimFlame Table 46: Homeowner Replacement Parts 42” 54” Description Catalog Number Catalog Number Remote Control Transmitter Kit H8753 H8753 Glass Door...
  • Page 69: Replacement Parts

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 70 Innovative Hearth Products Installation and Operation Instructions Superior DRL 6000 Series Direct-Vent Gas Fireplaces 900077-00, 03/2014 www.SuperiorFireplaces.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses...

This manual is also suitable for:

Drl6554ten

Table of Contents