Rebooting and Reconfiguring
In most cases, the "Protocol" field should be set to "Bell" or "CCITT". In the United
States, the protocol is usually "Bell." In Europe, the protocol is usually "CCITT."
The "Autodial Protocol" should match that of the modem.
5. If you need to change parameters, enter Y in response to the prompt. The system
displays a change menu:
Enter your change.
Current bit rate is 9600 bits/sec.
(0=300, 1=1200, 2=2400, 3=4800, 4=9600, 5=19200): 2
Current Protocol is CCITT.
(0=CCITT, 1=Bell, 2=CCITT_BIS): 1
Current Autodial Protocol is V25.BIS.
(0=V25.bis, 1=Hayes): 1
Current System identification: System_name
New system identification (limited to 1 to 23 displayable characters
or space for none): (New_system_name)
New configuration (takes effect at next remote connection):
Bit rate:
Protocol:
Autodial Protocol:
System identification:
6. An N response to the prompt in step 5 returns the CM> prompt.
7. From the system prompt CM>, enable remote access by a remote console command ER:
CM> ER
8. The system responds with the following display:
Current remote console access configuration:
Remote CS:
Mode:
Password:
Password faults:
Do you wish to change the configuration? (Y/N):
The "Remote CS" parameter enables the Copy Screen (CS) to be executed from the
remote console. The CS command copies a screen from the local console to the remote
console.
The "Mode" field determines whether only one remote access will be permitted (Single)
or many (Multiple).
3-72
<CR> retains the current value.
Select the new bit rate.
Select the new protocol.
Select the new protocol.
2400 bits/sec
Bell
Hayes
System_name
Enabled
Multiple
(current password)
03