Checking The Sp Error Log - HP 3000 99x Family Installation Manual

9000 systems t- class
Table of Contents

Advertisement

Figure 3-24
Indicator Grid on the SP Card
Table 3-8
Normal States of Lights in Service Processor (SP) Grid
Condition
During SP selftest
SP selftest failure
After SP selftest
At PDC prompt or whenever
PDC is active
At SP prompt
If the indicators show normal status as described in the proceeding tables, the system
has passed its selftests. Continue to the next section.
If the indicators do not match those shown, refer to the troubleshooting chapter in the
CE Handbook (PN A1809-90003) and look at the SP error log.

Checking the SP Error Log

Before loading the operating system, it is a good idea to check the Service Processor (SP)
error logs, correct any problems, and clear the logs:
Chapter 3
State of Lights
ST lit; numbered lights are lit so that the
sum of the numbers equals the SP selftest
in progress.
ST lit; numbered lights lit, so that the sum
of the numbers equals the SP selftest that
failed.
ST not lit; CK flashes ON and OFF at one
second intervals. Also, CT (SPP) and CR
(SPP) flash at one minute intervals as the
SP and the Console/LAN card handshake.
T (CPP) and R (CPP) flash during console
input/output.
CT (SPP), CR (SPP), DT (SPP), and DR
(SPP) flash during console input/output.
Installation
Verifying the System
3-55

Advertisement

Table of Contents
loading