Incorporation Of The Power Supply Unit And Fan Unit Of The; Sparc M10-4/M10-4S - Fujitsu M10-4 Service Manual

Hide thumbs Also See for Fujitsu M10-4:
Table of Contents

Advertisement

270.....300.....330.....360.....390.....420.....450.....480.....510.....-
540.end
Initial   diagnosis   has   completed.
PSB   power   off   sequence   started.   [1200sec]
    0.....   30.....end
PSB   powered   off.
PSB     Test         Fault
----   -------   --------
00-0   Passed     Normal
done
4.
Confirm that the status is normal ("Normal") after the replacement, and then
enter "f".
------------------------------------------------------------------------------
Maintenance/Replacement   Menu
Status   of   the   replaced   FRU.
 
FRU                                   Status                
-------------------   --------------
/BB#0                               Normal                
------------------------------------------------------------------------------
The   replacement   of   BB#0   has   completed   normally.[f:finish]   : f
5.
When the maintenance menu appears, enter "c" to exit the operation.
------------------------------------------------------------------------------
Maintenance/Replacement   Menu
Please   select   the   chassis   including   replaced   FRU.
No.   FRU                                       Status
---   -------------------   --------------
1       /BB#0                                   Normal
2       /BB#1                                   Normal
3       /BB#2                                   Normal
4       /BB#3                                   Normal
------------------------------------------------------------------------------
Select   [1-4|c:cancel]   : c
6.2.2
Incorporation of the power supply unit and fan unit
of the SPARC M10-4/M10-4S
This section describes the procedure for incorporating an FRU into the system after
maintenance.
After replacing the FRU in step 7 in
fan unit of the SPARC
1.
After completing maintenance of the target FRU, return to the replacefru
command operation of the XSCF firmware, and enter "f".
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
94
"5.8.2 Releasing of the power supply unit and
M10-4/M10-4S," continue here.