270.....300.....330.....360.....390.....420.....450.....480.....510.....-
540.end
Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30.....end
PSB powered off.
PSB Test Fault
---- ------- --------
00-0 Passed Normal
done
4.
Confirm that the status is normal ("Normal") after the replacement, and then
enter "f".
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced FRU.
FRU Status
------------------- --------------
/BB#0 Normal
------------------------------------------------------------------------------
The replacement of BB#0 has completed normally.[f:finish] : f
5.
When the maintenance menu appears, enter "c" to exit the operation.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select the chassis including replaced FRU.
No. FRU Status
--- ------------------- --------------
1 /BB#0 Normal
2 /BB#1 Normal
3 /BB#2 Normal
4 /BB#3 Normal
------------------------------------------------------------------------------
Select [1-4|c:cancel] : c
6.2.2
Incorporation of the power supply unit and fan unit
of the SPARC M10-4/M10-4S
This section describes the procedure for incorporating an FRU into the system after
maintenance.
After replacing the FRU in step 7 in
fan unit of the SPARC
1.
After completing maintenance of the target FRU, return to the replacefru
command operation of the XSCF firmware, and enter "f".
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
94
"5.8.2 Releasing of the power supply unit and
M10-4/M10-4S," continue here.