Note - For the versions of XCP and Oracle VM Server for SPARC/SRU that support dynamic
reconfiguration (DR) of a physical partition, see the latest Product Notes.
Note - To add or remove an I/O device in the control domain, you need to first transition the
domain to delayed reconfiguration mode. Then, add or remove the I/O device, and restart
the control domain.
1.
Confirm that the I/O device in the chassis requiring maintenance is not used
in the logical domain.
For details, see
or logical
2.
Log in to the XSCF shell.
3.
When the server requiring maintenance is operating as the master chassis,
execute the switchscf command to switch the master XSCF to a standby
XSCF.
Enter "y" in response to the confirmation message.
If the chassis requiring maintenance is the slave XSCF, go to step 5.
XSCF>   switchscf -t Master
The   XSCF   unit   switch   between   the   Master   and   Standby   states.
Continue?   [y|n]   : y
4.
Log in to the XSCF again.
5.
Execute the showboards command to check the status of the server
connected to the chassis requiring maintenance.
The BB-ID of the chassis requiring maintenance is indicated by the system board
(PSB) number.
In the following example, the [Fault] column displays "Degraded" for PSB 00-0,
indicating that the system board is operating with some faulty parts.
XSCF>   showboards -va
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         y         y         y         Passed     Degraded
01-0   00(01)               Assigned         y         y         y         Passed     Normal
02-0   00(02)               Assigned         y         y         y         Passed     Normal
03-0   00(03)               Assigned         y         y         y         Passed     Normal
6.
Execute the deleteboard command with the -c disconnect option specified to
release the chassis requiring maintenance from the physical partition.
In the following example, PSB 00-0 is released from the physical partition.
XSCF>   deleteboard -c disconnect 00-0
7.
Execute the showresult command to check the end status of the deleteboard
command that was just executed.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
70
"5.3.1 Checking the operating condition of the physical partition
domain" to
"5.4.1 Releasing the assignment of I/O
devices."