#   cfgadm -a
Ap_Id                               Type                   Receptacle       Occupant           Condition
BB#0-PCI#0                     pci-pci/hp       connected         configured       ok
6.
If the ATTENTION LED of the target cassette is blinking when you replace the
PCI Express card, turn off the ATTENTION LED.
#   cfgadm -x led=attn,mode=off <Ap_Id>
7.
Assign the I/O device of the incorporated PCI Express card to the logical
domain.
- If you have replaced a faulty PCI Express card, proceed to
virtual
- If you have added a new PCI Express card:
- If you are using XCP 2230 or later and Oracle VM Server 3.1.1.1 or later:
- If you are using XCP 2221 or earlier or Oracle VM Server 3.1.1 or earlier:
8.
If you have enabled the hotplug service, execute the svcadm command to
disable the hotplug service.
#   svcadm disable hotplug
Incorporation of an internal disk
1.
Log in as a super user to Oracle Solaris on the logical domain (control domain
or root domain) into which the target internal disk is to be incorporated.
2.
Execute the cfgadm(1M) command to check the status of the incorporated
internal disk.
With the cfgadm -al command, confirm that AP_ID of the replacement internal
disk has been changed.
Confirm that Occupant shows "configured." If it does not show "configured,"
perform step 3.
#   cfgadm -al
Ap_Id                                                   Type             Receptacle   Occupant      
Condition
  < Omitted >
c2                                                         scsi-sas     connected   configured      
device."
Perform operations according to the description in "15.3.1 Adding a
physical I/O device to an I/O domain" in the Fujitsu M10/SPARC M10 Systems
System Operation and Administration Guide.
Perform operations according to the description in "3.2.15 Configuring an
I/O device" and "3.2.16 Creating or destroying the SR-IOV virtual function"
in the Fujitsu M10/SPARC M10 Systems Domain Configuration Guide.