Incorporating An I/O Device - Fujitsu M10-4 Service Manual

Hide thumbs Also See for Fujitsu M10-4:
Table of Contents

Advertisement

command that was just executed.
The following example shows that "0" is returned as the end status and the
execution of the addboard command has been completed successfully.
XSCF>   showresult
0
4.
Execute the showboards command to confirm that the chassis requiring
maintenance has been incorporated into the physical partition.
The BB-ID of the server requiring maintenance is indicated by the system board
(PSB) number.
In the following example, [Fault] of PSB 00-0 displays "Normal", which indicates
that the system board is operating normally.
XSCF>   showboards -a 
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         y         y         y         Passed     Normal
01-0   00(01)               Assigned         y         y         y         Passed     Normal
02-0   00(02)               Assigned         y         y         y         Passed     Normal
03-0   00(03)               Assigned         y         y         y         Passed     Normal
5.
Execute the showstatus command to confirm that the FRU is operating
normally after the completion of maintenance.
Nothing is displayed if it is normal.
XSCF>   showstatus
6.
Execute the showhardconf command to check the hardware configuration
and the status of each FRU.
Confirm that no asterisk (*) is displayed in front of any FRU.
XSCF>   showhardconf
7.
If the state of the master chassis requiring maintenance has been switched to
the standby state before maintenance, execute the switchscf command to
switch the chassis to the master XSCF.
XSCF>   switchscf -t Standby
6.5.2

Incorporating an I/O device

This section describes the procedure (workflow) for incorporating an I/O device by
using the hot plug function.
Chapter 6 Restoring the System
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fujitsu m10-4s

Table of Contents