To prevent injury from propeller blades, wear gloves
and place a block of wood between the anti - cavitation
plate and the propeller blade tips to lock the propeller
in place.
Remove the two (2) bolts 1 securing the propeller shaft bear-
ing housing to the gearcase.
Using special tools, draw out the propeller shaft bearing hous-
ing.
Remove the propeller shaft and bearing housing assembly.
09930-30104 : Sliding hammer – A
09950-59310 : Propeller shaft remover – B
Loosen the four (4) nuts 3, then remove the water pump case
4, impeller 5, key 6 and pump under plate 7.
Keep the impeller key 6 for reuse and discard the plate gasket
8.