Suzuki DF 25 Service Manual page 221

Four stroke
Hide thumbs Also See for DF 25:
Table of Contents

Advertisement

9-16
POWER TRIM AND TILT
TRIM/TILT "DOWN" CIRCUIT
The electric motor is operating in a counterclockwise direction. Check valve B will open, allowing oil to flow
from the reservoir to the pump. Oil flow from the pump enters the spool valve, moving it to the right, thereby
opening the "up" pressure main check valve. Oil from the lower cylinder chamber will go through the "up"
pressure main check valve to the pump.
Pressure built up by the pump will open the "down" pressure main check valve and oil will enter the upper
cylinder chamber. The piston will retract (move inward), which will tilt the outboard down. Oil in the lower
cylinder chamber is returned to the pump through the "up" pressure main check valve.
When full "down" position is reached, continued operation of the "down" relay will have no effect, as pump oil
flow will be returned to the reservoir through the "down" relief valve.
Oil reservoir
PTT motor
"DOWN" relief valve
Spool valve
"DOWN" pressure
main check valve
Tilt rod
Piston
Check valve
Gear pump
"UP" pressure main check valve
Upper cylinder chamber
Lower
cylinder
chamber

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Df 30

Table of Contents