9-12
POWER TRIM AND TILT
PTT MOTOR RELAY
Two methods can be used to test PTT relays.
Method 1.
Measure resistance between wiring leads of the relay.
09930-99320 : Digital tester
Tester range :
UP
Light Blue
DOWN
PTT relay solenoid coil resistance :
Standard
3.0 – 4.5
Method 2.
Connect the wiring leads of the relay to battery (12V) and check
relay operation.
09930-99320 : Digital tester
Tester range :
When there is continuity between terminals 1
unit is considered to be without defect.
With Black lead wire connected to the battery negative (–) ter-
minal and Light blue or Pink lead wires are connected to bat-
tery positive (+) terminal there should be continuity between
4. . . . .
2
3
With the lead wires are disconnected from the battery there
should be no continuity between 3
The relay is considered to be without defect if continuity test
results are as stated above.
(Resistance)
Tester probe connection
Red (+)
Black (–)
Pink
(Continuity)
4.
Black
Black
2
3, the
B
2
1
B
3
4
CONT
2
B
3
4
1
CONT
12V BAT.
Lbl(P)
Lbl(P)
Lbl(P)