10-3. Indoor Unit

10-3-1. Installation Place

• A place which provides enough spaces around
• the indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
intake and discharge.
• A place which allows easy installation of the piping to
the outdoor unit.
• A place which allows the front panel to be opened.
• The indoor unit shall be installed so that the top of the
indoor unit is positioned at least 2m in height.
• Also, avoid putting anything on the top of the indoor
unit.
Remote controller
• Should be placed where there are no obstacles,
such as curtains, that may block the signal.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m away from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• Do not install near high-frequency devices or
wireless devices.
• The location of the remote controller should be
determined as shown below.
(Side view)
(Top view)
Reception
Remote
range
controller
*: Axial distance
Fig. 10-3-1
Indoor unit
Reception
range
Remote controller
10-3-2. Drilling and Mounting Installation Plate
Drilling
When installing the refrigerant pipes from the rear.
1
m from
unit edge
100 mm to pipe
hole enter
1) Decide the installation plate mounting position on
the wall.
2) Mark the corresponding pipe hole wall positions
according to the positioning marks (]) on the
installation plate.
3) Drill the pipe holes (Dia. 65 mm or Dia. 80 mm)
slightly slanted downward to the outside.
NOTE
• When drilling into a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
• The unit is designed to enable installation using
holes of 65 mm in diameter.
However, if installation is difficult, make holes that
are 80 mm in diameter.
CAUTION
Completely fill in the gaps in the pipe holes with
noncombustible material (such as putty) to prevent
condensation and fire in the casing.
Mounting the installation plate
Positions recommended for
securing the screws (4 places)
Anchor bolt holes
Level (magnetic-backed)
holder
Indoor unit
Pipe hole
– 83 –
100 mm
Pipe
hole
45 mm
Fig. 10-3-2
[1] Installation plate
Pipe hole
[5] Mounting screw
Dia. 80 mm