Toshiba RAS-M10PKVP-E Service Manual page 47

Air conditioner (split type)
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

<Cooling> (Continued)
No. of
Temperature condition
operating
Indoor
Outdoor
units
3 units
27/19
35/-
4 units
NOTES:
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor
thermometer)
2. Connecting piping condition : 5 meters × 4 units (5 m / each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MP)
18
16
07
-
0.8 to 1.0
22
16
07
-
0.8 to 1.0
24
16
07
-
0.8 to 1.0
18
18
07
-
0.8 to 1.0
22
18
07
-
0.8 to 1.0
24
18
07
-
0.8 to 1.0
10
10
10
-
0.8 to 1.0
13
10
10
-
0.8 to 1.0
16
10
10
-
0.8 to 1.0
18
10
10
-
0.8 to 1.0
22
10
10
-
0.8 to 1.0
24
10
10
-
0.8 to 1.0
13
13
10
-
0.8 to 1.0
16
13
10
-
0.8 to 1.0
18
13
10
-
0.8 to 1.0
22
13
10
-
0.8 to 1.0
24
13
10
-
0.8 to 1.0
16
16
10
-
0.8 to 1.0
18
16
10
-
0.8 to 1.0
22
16
10
-
0.8 to 1.0
24
16
10
-
0.8 to 1.0
18
18
10
-
0.8 to 1.0
22
18
10
-
0.8 to 1.0
24
18
10
-
0.8 to 1.0
13
13
13
-
0.8 to 1.0
16
13
13
-
0.8 to 1.0
18
13
13
-
0.8 to 1.0
22
13
13
-
0.8 to 1.0
24
13
13
-
0.8 to 1.0
16
16
13
-
0.8 to 1.0
18
16
13
-
0.8 to 1.0
22
16
13
-
0.8 to 1.0
24
16
13
-
0.8 to 1.0
18
18
13
-
0.8 to 1.0
22
18
13
-
0.8 to 1.0
16
16
16
-
0.8 to 1.0
22
16
16
-
0.8 to 1.0
07
07
07
07
1.0 to 1.2
10
07
07
07
1.0 to 1.2
13
07
07
07
1.0 to 1.2
16
07
07
07
1.0 to 1.2
18
07
07
07
1.0 to 1.2
22
07
07
07
1.0 to 1.2
Only SKV series allowed
24
07
07
07
1.0 to 1.2
Only SKV series allowed
10
10
07
07
1.0 to 1.2
13
10
07
07
1.0 to 1.2
16
10
07
07
1.0 to 1.2
18
10
07
07
1.0 to 1.2
22
10
07
07
1.0 to 1.2
Only SKV series allowed
24
10
07
07
1.0 to 1.2
Only SKV series allowed
Heat exchanger
pipe temperature
T1 (ºC)
T2 (ºC)
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
11 to 13
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
15 to 17
51 to 53
– 47 –
Compressor
Indoor fan
Outdoor fan
revolution
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
(rps)
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
59.8
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2
62.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m16pkvp-eRas-m18pkvp-eRas-4m27uav-eRas-m13pkvp-e

Table of Contents