No. Part name
7
Replacement
1. Reactor to be attached to the inverter assembly
of reactor
1) Perform works of Detachment 1 of 1 and 4.
2) Remove the relay connector of the reactor.
3) Remove the reactor cover.
(Truss head B tight screw Ø4 × 6, 4 pcs.)
4) Remove the reactor. (ST1T Ø4 × 6, 2 pcs.)
5) Mount a new reactor.
2. Reactor to be attached to the partition plate
1) Perform works of Detachment 1 of 1 and 4.
2) Remove the reactor from the partition plate.
(ST1T Ø4 × 8, 2 pcs.)
3) Mount the front panel.
∗ Caution to mount the inverter assembly.
When mounting the inverter assembly to the partition
plate, be sure to attach the hooks certainly.
Procedure
Hooks
Partition
plate
– 139 –
Remarks
Reactor cover
Reactor
relay connector
Reactor cover
Reactor
Partition plate
Reactor