Toshiba RAS-M10PKVP-E Service Manual page 95

Air conditioner (split type)
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

D800
D801
Before check
During check
Check results
LED
D802
D803
D804
D805
– 95 –
: LED ON,
: LED OFF,
Description
Normal operation (no error)
Checking A unit
Checking B unit
Checking C unit
Checking D unit
Normal operation (no error)
Trouble in unit A
Trouble in unit B
Trouble in unit C
Trouble in unit D
Trouble in unit A and B
Trouble in unit A and C
Trouble in unit A and D
Trouble in unit A
Trouble in unit B and C
Trouble in unit B and D
Trouble in unit B
Trouble in unit C and D
Trouble in unit C
Trouble in unit D
Trouble in unit A,B and C
Trouble in unit A,B and D
Trouble in unit A,B
Trouble in unit A,C and D
Trouble in unit A,C
Trouble in unit A,D
Trouble in unit B,C and D
Trouble in unit B,C
Trouble in unit B,D
Trouble in unit C,D
Trouble in unit A,B,C and D
Trouble in unit A,B,C
Trouble in unit A,B,D
Trouble in unit A,C,D
Trouble in unit B,C,D
"Trouble in all units service valve stays closed"
: LED Flash

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m16pkvp-eRas-m18pkvp-eRas-4m27uav-eRas-m13pkvp-e

Table of Contents