Framing Dimensions - Regency Horizon HZ42STEPV Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION
A *
Framing Depth *
B
Framing Height
C
Framing Width
D
Gas Connection Height
E
Gas Connection Inset
F
Gas Connection Opening Width
G
Gas Connection Opening Height
H
Minimum Height to Combustibles
* Framing depth measurement is noted with nailing strips (top & sides) set as far forward on the fi rebox
as possible. The nailing strips can be adjusted back up to 1" (on both sides) to allow for varying
thicknesses in non-combustible material and wall fi nishes.
**Finished material thickness includes: non combustible material, tile slate, etc.
(example framing = 13" - if 1" thick fi nishing material is used on both sides)
IMPORTANT:
1/2" gap required between
faceplate and fi nished wall.
Dangerous operating
conditions will occur if this is
not adhered to.
1/2"
Note: Gas hookup is on vent side of unit.
14

FRAMING DIMENSIONS

HZ42STEPV Framing Dimensions
1/2"
All studs
are metal
(on edge)
15" (381mm)
**minus 2X the fi nished material thickness
36-3/4" (933mm)
50" (1270mm) Horizontal or Vertical Vent
4-1/2" (114mm)
2-7/8" (73mm)
4-5/8" (117mm)
2" (51mm)
40-1/2" (1029mm)
B
C
Note: All studs on top and sides of unit must be on edge.
A
Regency Horizon™ HZ42STEPV Gas Fireplace
H
Finished
Floor

Advertisement

Table of Contents
loading

Table of Contents