Gas Power Vent Installation; Rigid Pipe Only - Regency Horizon HZ42STEPV Owners & Installation Manual

Table of Contents

Advertisement

The Power Vent System is a Direct Vent Terminal designed to allow installation of gas appliances where typical vent confi gurations cannot be achieved.
These installation instructions must be used in conjunction with the appliance and appropriate Power Vent components installation instructions.
120 Volt power supply is required to operate this system (see Electrical Installation section in this manual).
Clearances listed in these Instructions supersede those in the appliance's Installation Instructions.
Models Equipped with Surefi re Ignition
The power vent system can only be used with units that have been tested with the Regency Power Vent system.
Downward vertical vent runs are permitted with the Surefi re Ignition system. See vent confi guration in this manual.
946-705 Power Vent Kit with Vent Terminal
1
510-994
Rigid Pipe adaptor
1
46
8-1/2" Slip section - or
DVA-08A
1
46
16" Slip section
DVA-16A
1
911-046
Power Vent Fan
1
Firestop
946-706
20' 5-wire BX cable - or
946-707
60' 5-wire BX cable
amount required
4"x 6-5/8" Rigid Pipe
for install
1
946-705
Power Vent Kit
POWER VENT SYSTEMS ARE FOR USE WITH RIGID PIPE ONLY.
See venting in this manual for detailed instructions.
Regency Horizon™ HZ42STEPV Gas Fireplace

GAS POWER VENT INSTALLATION

Rigid Pipe Adaptor
(included w/unit)
BX Cable
(sold separately)
Parts Required
included with unit
sold separately
sold separately
included w/power vent kit
included w/power vent kit
sold separately
sold separately
sold separately
sold separately

RIGID PIPE ONLY

4" x 6-5/8" Rigid pipe lengths
(sold separately)
Slip Section
(sold separately)
INSTALLATION
Firestop Spacer
(w/Power vent kit)
Frame Assembly
(w/Power vent kit)
Power Vent Terminal
(946-705)
17

Advertisement

Table of Contents
loading

Table of Contents