Regency Horizon HZ42STE-NG Owners & Installation Manual

Horizon hz42ste natural gas and propane fireplace
Table of Contents

Advertisement

Regency Horizon
Horizon HZ42ST Product Video
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-944a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
Installer
: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
HZ42STE
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
42
MODELS:
HZ
STE-NG Natural Gas
HZ
42
STE-LP Propane
www.regency-fi re.com
09/12/13

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZ42STE-NG

  • Page 1 Owners & Regency Horizon HZ42STE ™ Installation Manual Gas Fireplace MODELS: STE-NG Natural Gas STE-LP Propane www.regency-fi re.com Horizon HZ42ST Product Video WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi...
  • Page 2 As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ®...
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 4: Table Of Contents

    Unit Installation with Horizontal Termination ....28 4" x 6-5/8" venting ............28 Unit Installation with Horizontal Termination ....29 Unit installation with Vertical Termination ....30 4" x 6-5/8" venting ............30 High Elevation Gas Line Installation ......31 Pilot Adjustment ............31 Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 5: Safety Label

    MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. 4001172 Minimum Clearances to Combustibles / APPAREIL FONCTIONNANT AU NATURAL GAS Degagement Minimum De Materiaux Combustibles NATURAL GAS: Model HZ42STE-NG CONCU POUR ETRE POELE: Mod le HZ42STE-NG é Side Walls Minimum supply pressure Pression d'allimentation minimum 5.0"...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 7: Dimensions

    UNIT DIMENSIONS 48-11/16” 1237mm 3” 76mm 41-3/16” 1046mm 1-1/2” 38mm 18-7/8” 479mm 36-1/2” 927mm 21-5/8” 30-13/16” 28-5/8” 549mm 783mm 727mm ½” 13mm 12” 1-1/2” 305mm 38mm 15” 381mm 12-7/8” 23-5/8” 327mm 36” 600mm 914mm 48-3/4” 1238mm Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 8: Installation

    8) To prevent injury, do not allow anyone who is SHOULD STAY AWAY TO AVOID BURNS unfamiliar with the operation to use the fi replace. OR CLOTHING IGNITION. 9) Wear gloves and safety glasses for protection while doing required maintenance. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 9: Installation Checklist

    Note: For Exterior Vent Termination Before leaving this unit with the customer, the Locations see section "Exterior Vent installer must ensure that the appliance is fi ring correctly and operation fully explained to Termination Locations." customer. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 10: Clearances

    Metal Stud Metal Stud on edge on edge 57" (1448mm) Vent End Non-combustible Material Note: Non-combustible material always wider at vent end 41-7/16” 9-3/8” (238mm) Non-combustible Material 6 - 3/8" (162mm) 4-1/4” (108mm) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 11: Mantel Leg Clearances

    1.5" (38mm) 1.5" (38mm) 9-1/2”(241mm) MANTEL LEG 9-1/2”(241mm) MANTEL LEG Non-Combustible Non-Combustible 1.5" (38mm) 1.5" (38mm) 9-1/2” (241mm) 9-1/2” (241mm) Allowable mantel Allowable mantel leg projection leg projection 13.5” (343mm) 13.5” (343mm) 16.5” (419mm) 16.5” (419mm) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 12: Unit Assembly Prior To Installation

    - tighten screws to secure. Extender can be adjusted to max. 15-1/2". 2) Remove the 3 screws near the vent outlet on the fi rebox - as shown below. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 13: Framing & Finishing

    fi nishing around the faceplate, the minimum opening dimensions Unit noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 1-1/2" 0" (fl ush) Nailing Strip Flush w/unit Factory Set Unit Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 14: Framing Dimensions

    Finished conditions will occur if this is Floor not adhered to. Note: All studs on top and sides of unit must be on edge. 1/2” 1/2” Note: Gas hookup is on vent side of unit. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 15: Vent Restrictor Position

    SET 0 THIS HOLE SETS THE THIS HOLE SETS THE THIS HOLE SETS THE THIS HOLE SETS THE VENT RESTRICTOR VENT RESTRICTOR VENT RESTRICTOR VENT RESTRICTOR AT 3/4” AT 1-1/4” AT 2-1/2” AT 3” FACTORY SET Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 16: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 17: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    Offset Support 46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 18 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 19: Venting Introduction

    Firestops are required at each fl oor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. • Flex system can only be used up to 10 feet - otherwise rigid venting must be used. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 20: Horizontal Terminations

    S.S. screws #8 x 1-1/2” drill point Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency ® may be used for Flex installations 3) Horizontal vent must be supported every 3 feet.
  • Page 21: Rigid/Fl Ex Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, ICC Excel, MetaFab, Security Secure Vent ® , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 22: Horizontal Terminations

    5' Max. 9' Min. 8' Max. required. between 90 elbows 6' Min. 8' Max. 6' Max. 11' Min. 9' Max. is required. Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 23 1 f o o t 6' Min. 5' Max. 10' Min. 8' Max. between 90 elbows 7' Min. 6' Max. 12' Min. 9' Max. is required. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 24: Venting Arrangement For Vertical Terminations

    Set 0 (factory setting) to Set 1 to Set 2 or Set 3 if required. Note: Must use optional fl ue adaptor when using Rigid Pipe (Part # 510-994). Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 25: Vertical Terminations

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , ICC Excel, Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 26: Vertical Terminations

    90 elbows is 5' Max. 5' Min. required. 6' Max. 6' Min. Restrictor Position - Set 0 (factory setting) For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 27 Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Restrictor Position - Set 0 (factory setting) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 28: Unit Installation With Horizontal Termination

    3 supplied screws (drilling pilot holes will make this easier). 4) Level the fi replace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 Diagram 1 Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 29: Unit Installation With Horizontal Termination

    Apply Mill Pac or high temperature silicone to the outer fl ex pipe and slip it over the outer fl ue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 30: Unit Installation With Vertical Termination

    Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 31: High Elevation Gas Line Installation

    Note: Any damage due to carboning resulting screw (clockwise) with a 1/8" fl at screwdriver. from improperly setting the aeration Note: Screw should be snug, but do not over controls is NOT covered under warranty. tighten. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 32: Battery & On | Off Switch Installation

    3) Disconnect connector from battery holder and remove from tray – (battery holder is attached by Velcro to tray). 4) Install - 4 AA batteries, reconnect the connector to the battery pack and put back onto Velcro strip Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 33: Wiring Diagram

    AC Adaptor (see AC Adaptor in *Wire Clamp Receptacle *Receptacle Box in Unit inside stove * = supplied with fan kit Other parts are to be supplied by electrician or installer *Receptacle (dedicated use by unit fan only) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 34: Optional Accent Lighting Wiring Diagram

    INSTALLATION OPTIONAL ACCENT LIGHTING WIRING DIAGRAM Wall Mounted Switch Optional Accent Lights Neutral Receptacle in Unit Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 35 5) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: (keep wires away from the heat as much as possible). FCM - COM Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 36: Optional Wall Thermostat

    Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details Note: Regency Profl ame systems include a white and black wall cover & switch.
  • Page 37: Gt Remote Installation

    Note: DO NOT USE 4 AA batteries in the battery pack on the tray - the DFBC is now powered by the receiver batteries in the wall. HZ42E HZ42STE 4) Remove the 4 AA batteries if installed, reconnect the connector to the battery pack and put back onto Velcro strip Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 38: Gtm Remote Installation

    (TH) 8) Install the stepper motor in the same location the hi/lo knob was Green to (DFBC) Green and (TH/TP) White to (DFBC) White removed from - with 2 screws as shown below. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 39 13) Program Receiver and transmitter (refer to manual) Note: DO NOT USE 4 AA batteries in the battery pack on the tray; the DFBC is now powered by the receiver batteries in the wall. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 40: Optional Refl Ective Panel Installation

    4) Orient the panel with the folds facing the wall of the fi rebox. Panel Clip The thin unfolded edge should be facing down towards the fl oor of the fi rebox. Thin edge facing down Fold facing 8) Reverse step 2 and 1. Thin edge faces downward Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 41: Optional Light Installation

    (use screws from cover plate). 4) Remove the glass door - see instructions in manual. 5) Remove the glass crystals/optional ceramic stones or pebbles- if installed. 6) Remove inner panels if installed - see instructions in manual. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 42 Note: Oils from hands will shorten the life of the bulbs, do not handle bulbs with bare hands. 14) Place gasket over the inside perimeter of the light diffuser box. Install socket and bulb into light diffuser as shown below. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 43: Bulb Replacement

    24) Reconnect electrical supply - test lights. 25) Reverse steps 8 -2. 5) Replace bulb. Note: Oils from hands will shorten the life of the bulbs, do not handle bulbs with bare hands. 6) Reverse steps 3 through 1. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 44: Glass Crystals Or Optional Stones Installation

    1-2/3 packages (5 x bags pebbles) HZI390E /HZI390PB 3 lbs 1 package (3 x bags pebbles) HZI234E 2 lbs 1 package (3 x bags pebbles) HZO42 / HZO42 (AUS) 3 lbs 1 package (3 x bags pebbles) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 45 Natural River Pebbles shown surrounding the a Horizon Burner Glass Crystals shown surrounding the Burner Glass Crystals shown on Burner and Firebox Floor For Units HZI390E, HZI540E DO NOT block pilot area with glass crystals Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 46: Optional Log Set Installation

    HZ42STE = 2lbs Notch in Log 3 5. Locate and install paper templates on both sides of fi rebox base as shown below. Back Front Diagram 2 Diagram 5 Front and back paper templates in position Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 47 Do not place lava rocks/embers too close to logs as this may cause carboning. 13. Carefully remove paper templates. 14. Adjust aeration, see unit manual for setting. 15. Reverse Steps 2 and 1. HZ42STE - Final Install Diagram 8 Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 48: Glass Door Installation

    See Diagram 2. 2) With the door in proper position - secure with 3 screws in locations shown in Diagram 3. Hook top of door onto top flange Flush Door Diagram 1 Diagram 2 Diagram 3 Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 49: Faceplate Installation

    6) Install the brackets onto the lower faceplate. Note: Installation location of the left and right brackets is the same for both the HZ42 and HZ42ST. Top of lower faceplate Right bracket shown in position on lower faceplate. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 50 - see step 2. 11) Final installation of faceplate on HZ42 unit HZ42ST - install slider on this side of the bracket. Note: Two faceplates need to be installed on the HZ42 ST unit. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 51: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 52: Copy Of Lighting Plate Instructions

    If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual. Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628b Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 53: Maintenance Instructions

    WARNING: Do not operate the manufacturer's instructions. appliance with the glass panels removed, cracked or broken. 8) Verify operation after servicing. Replacement of the glass panels should be done by a licensed or qualifi ed service person. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 54: Glass Door Removal

    4) Remove the glass door - see manual for detailed instructions. a) Remove the 3 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom and lift up and out. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 55: Valve Tray Replacement

    8) Disconnect the ON/OFF connector wires from the valve. ON/OFF Connector Wires 9) Remove the valve assembly by undoing 12 screws. 5) Remove bottom cover by lifting up and out. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 56 MAINTENANCE 10) Partially lift out valve tray. 11) Disconnect the inlet gas line and remove the valve assembly. 12) Replace the valve assembly and reverse steps. Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 57: Parts List

    910-882 Wire (Valve to Burner ON/OFF) 911-013 Wire Harness Incl. IP/CP switch 918-944 Manual 8) 904-593 Orifi ce # 40 (NG) 904-345 Orifi ce # 53 (LP) 9) 948-484 Slide Hinge 911-012 Ignition Board (DBC) Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 58: Accessories

    GTM Profl ame Surefi re™ Remote Control 946-693 GTM NG Surefi re™ Modulator 946-694 GTM LP Surefi re™ Modulator 911-028 GTM Surefi re™ Wire Harness 910-576 Cover Wall Mount (white) 910-572 Receiver GTM SIT w/Batt & Cover Regency Horizon™ HZ42STE Gas Fireplace...
  • Page 59: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 60 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Horizon HZ42ST Product Video Regency Horizon is a trademark of FPI Fireplace Products International Ltd. © Copyright 2013, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Horizon hz42ste-lpHorizon hz42ste

Table of Contents