VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS

The gas power vent systems is designed to allow the installation of a gas appliance when typical vent confi gurations (shown in this manual) are not
possible.
Note: Must be terminated horizontally. Vertical terminations are not permitted.
0
2
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
-2
-4
-6
-7 ft. max
0
2
Maximum total vent length = 50' + six - 90° elbows.
One 90° elbow = two 45° elbows.
Maximum total negative vent length = 10' (from centerline of pipe).
Restrictor setting 1 - Max. up to six- 90° elbows.
Restrictor setting 2 - Max. up to five- 90° elbows.
Restrictor setting 3 - Max. up to four- 90° elbows.
Note: Must be terminated horizontally. Vertical terminations are not permitted.
Regency Horizon™ HZ42STEPV Gas Fireplace
(RIGID PIPE 4" X 6-5/8" - MUST USE RIGID PIPE ADAPTOR #510-994)
6
8
4
10
12
14
4
6
8
10
12
14
Horizontal (Feet)
16
18
20
22
24
26
Restrictor Setting
#1 - 0.75" open
Restrictor Setting
#2 - 1-1/4" open
Restrictor Setting
#3 - 1-3/4" open
26
16
18
20
22
24