Superior DRC3035DEN Installation And Operation Instructions Manual page 9

Direct-vent gas fireplacesdrt3000 and drc3000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT/C3000 Series Direct-Vent Gas Fireplaces
TM
BTU Input
Table 1: Input Rate (BTU/HR), Gas Valves
† 12,000 in Superior Contemporary Models
Table 2: Thermal Efficiency (%)
* AFUE is a measurement of the US Department of Energy, ** P4 (EnerGuide) is a measurement of the Canadian Office of Energy Efficiency.
Efficiencies are based on Normal input operation.
Gas Pressure
Table 3: Inlet Gas Supply Pressure
Table 4: Manifold Gas Supply Pressure
Test gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the
inlet and OUT for the manifold side). The control valves have a 3/8" (10 mm) NPT thread inlet and outlet side of the
valve (Figure 1 and Figure 2).
Figure 1: Millivolt Gas Valve
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down
regulators to reduce the pressure to safe levels.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Models
33" Models
35" Models
40" Models
45" Models
Model
AFUE *
33" Models
35" Models
40" Models
45" Models
Fuel
Natural Gas
Propane
Fuel
Natural Gas
Propane
Figure 2: Electronic Gas Valves
Natural Gas
High Rate
Low Rate
14,000
10,500
16,000
11,000
20,000
14,000
21,500
13,500
Millivolt
P4 **
65
60
66
61
66
61
67
61
Minimum
5" WC / (1.25 kPa)
11.0" WC / (2.74 kPa)
Traditional Model Pressure
3.5" WC / (0.87 kPa)
10.0" WC / (2.49 kPa)
Traditional
General Information
900285-00 05/2015
Propane Gas
High Rate
Low Rate
13,000
9,500
15,000
11,000
19,000
14,000†
21,500
13,500
Electronic
AFUE *
P4 **
65
63
66
63
66
63
67
63
Maximum
10.5" WC / (2.61 kPa)
13.0" WC / (3.23 kPa)
Contemporary Model Pressure
3.8" WC/ (0.95 kPa)
9.8" WC (2.44 kPa)
Contemporary
9