Superior DRT6340TYN Installation And Operation Instructions Manual

Superior drt/drc6300 series powervent direct vent gas fireplaces

Advertisement

Quick Links

P/N 900344-00 Rev. NC 01/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900344-02.
P900344-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
DRT/DRC6300 Series Powervent Direct Vent Gas
Fireplaces
PFS
Models
DRT6340TYN
®
DRC6340TYN
C
US
Report No. F14-106
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
• Si vous ne pouvez rejoindre le fournisseur de
— L'installation et l'entretien doivent être assurés par
AVERTISSEMENT:
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
gaz depuis un voisin. Suivez les instructions du
fournisseur.
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT6345TYN
DRC6345TYN

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRT6340TYN

  • Page 1 Installation and Operation Instructions DRT/DRC6300 Series Powervent Direct Vent Gas Fireplaces P/N 900344-00 Rev. NC 01/2015 Models Ce manuel est disponible en francais, simplement DRT6340TYN DRT6345TYN ® en faire la demande. Numéro de la pièce 900344-02. DRC6340TYN DRC6345TYN Report No. F14-106 P900344-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information Superior DRT/DRC6300 Powervent Series Direct-Vent Gas Fireplaces 900344-00 01/2015 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace

    Innovative Hearth Products General Information Superior DRT/DRC6300 Powervent Series Direct-Vent Gas Fireplaces 900344-00 01/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 4: Table Of Contents

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS TABLE OF CONTENTS GENERAL INFORMATION PACKAGING WARNING The assembled vented gas fireplace is packaged with: Safety and Your Fireplace ....Page 3 Important Safety Information ..Page 4 Young children should be care- BOX 1 - Fireplace: Packaging .........Page 4 •...
  • Page 5 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Codes and Standards WARNING WARNING These appliances comply with National Safety Improper installation, adjust- Failure to position the parts in Standards and are tested and listed by PFS (Re- port No.
  • Page 6: Massachusetts Requirements

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Gas Pressure - All Models PURGE CYCLE Burner Orifice Size This is a power vented fireplace that Elevation 0 - 4500 ft (0 - 1370 m) Tables 2 and 3 show the appliance inlet and requires household electrical power manifold gas pressure requirements.
  • Page 7: Cold Climate Insulation

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS • A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade and be directly in line with NOTE: When the unit is installed the horizontal termination.
  • Page 8: Vent Termination Clearances

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS VENT TERMINATION CLEARANCES Combustible Projection 2-1/2" or less in length These instructions should be used as a guide- line and do not supersede local codes in any Combustible Projection way.
  • Page 9 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Inside Corner Outside Corner Recessed Location See Figure 4 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA...
  • Page 10: Minimum Clearances To Combustibles

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUSTIBLES MANTEL CLEARANCES Inches (mm) Appliance And Vent Clearances 12 (305) MANTEL The appliance is approved with zero clearance to combustible materials 10 (254) MANTEL on all sides.
  • Page 11: Pre-Installation Steps

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION SEQUENCE PRE-INSTALLATION STEPS DETAILED INSTALLATION STEPS The typical sequence of installation is outlined Step 1. FRAMING The appliance is shipped with all gas controls and components installed and pre-wired. below.
  • Page 12: Fireplace And Framing Specifications

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS FIREPLACE AND FRAMING SPECIFICATIONS Framing should be constructed VENT FRAMING of 2x4 or larger lumber. Adaptor Plus 4 ft TOP VENT WITH 2 FEET 10-1/2” Vertical Vent VERTICAL VENT AND (267) ONE 90°...
  • Page 13 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Schedule 40 Black Iron Pipe Inside Diameter Length Inside Diameter 0 - 10 ft (0 - 3.1 m) 1/2" (12.7 mm) 10 - 40 ft (3.1 - 12.2 m) 1/2"...
  • Page 14: General Vent Information

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Power Vent Components Step 3. INSTALL THE VENT SYSTEM General Information Locate the fireplace as instructed in this manual. Make the following modifications to add the com- ponents used with the Power Vent Kit.
  • Page 15: Vent Section Length Chart

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS VENT SECTION LENGTHS i t c i t c O O O O O O O O O O T T T T T T T T T T A A A A A A A A A A Determine the number of straight vent sections...
  • Page 16 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS A. Frame ceiling opening - Use a plumb line The unitized design of the Secure Vent com- E. Support the vertical vent run sections - ® ponents will engage and seal both the inner and from the ceiling above the appliance to locate outer pipe without the need for sealant or screws.
  • Page 17 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS VENT FIGURES NOTES: • Secure Vent components (rigid vent pipe and terminal) are shown. ® • Two 45° elbows may be used in place of one 90° elbow. •...
  • Page 18: Horizontal Termination System

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS HORIZONTAL (OUTSIDE WALL) D. Attach vent components to appliance - To G. Support the vertical run sections - attach a vent component to the appliance TERMINATION SYSTEM On the vertical run, support the venting system collar, align the dimpled end over the collar, every eight feet (2.4 m) above the fireplace...
  • Page 19 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS L. Install Firestop/Spacer at exterior wall - Power Vent Install SV4.5HF Firestop/Spacer, provided To help minimize water infiltration Termination with the power vent kit, over the opening at it is recommended that the Firestop/Spacer (SV4.5HF) the exterior side of the framing, long side be installed on the exterior side of the wall.
  • Page 20: Typical Installation Sequence

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Step 4. FIELD WIRING • Refer to Figure 25 on Page 21 and install the electrical hardware on the ends of the cable. Male terminals on the Black and White wires, CAUTION: Label all wires prior to disconnection when servic- and ring terminals on the ground wire.
  • Page 21 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Wiring - Fireplace (See Figures 27 and 28 on Page 22) • Refer to Figure 26 and install the electrical hardware on the fireplace end of the cable. Male terminals (#10) on the Black and White wires, NOTE: These electronic appliances must be connected to the main and ring terminals (#9) on the ground.
  • Page 22 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS ELECTRONIC WIRING DIAGRAM Flame IPI Pilot Sensor (Schematic representation only) Spark Electrode Pilot Tube Optional Split Flow COLOR CODE: 885 Valve B = Black Battery Holder with Switch Battery Holder w/Switch BB = Brown w/Black Stripe ON/Remote/OFF...
  • Page 23 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Step 6. CONNECTING GAS LINE Turn on gas supply and test for gas leaks using NOTE: Lighting Instructions are also found on a gas leak test solution (also referred to as the literature tag tied to the bracket above the All codes require a shut-off valve mounted in bubble leak solution).
  • Page 24 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Step 9. INSTALL VOLCANIC STONE, GLOWING EMBERS, AND Firebox Accessories LOGS (Traditional Only), or GLASS MEDIA (Contemporary Only) Cat. No. Model Description 88L53 Bag of Glowing Embers NOTE: If installing the contemporary burner/floor kit, skip 80L42 FDVS...
  • Page 25 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Traditional Only: Log Placement Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate. Figure 37 - Placing Logs 3 and 4 Log Number Description Log, Center...
  • Page 26 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Step 11. BURNER ADJUSTMENTS Step 10. INSTALLATION AND REMOVAL WARNING: Any safety screen or guard re- moved for servicing the appliance must be OF GLASS DOOR Flame Appearance and sooting replaced prior to operating the appliance.
  • Page 27 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS • An appliance operated with the air shutter opened too far, may have flames that appear blue and transparent. These weak, blue and Air Shutter Opening transparent flames are termed anemic. The following chart is provided to aid in correctly adjusting the air shutter.
  • Page 28 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS FINISHING REQUIREMENTS Noncombustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with the exceptions. Wall Details Vertical installation clearances to combustible mantels vary according to Complete the finished interior wall.
  • Page 29: Attaching Safety-In-Operation Warnings

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Step 12. INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 30: Installation Accessories

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Listed Secure Vent Components Listed Secure Vent / Secure Flex Components ® ® Cat. No. Model No. Description Cat. No. Model No. Description 6" (152mm) 77L70 SV4.5L6 Vent Section Attic Insulation Shield H3907...
  • Page 31 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué...
  • Page 32 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS ATTACHING SAFETY-IN-OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety Votre foyer a été...
  • Page 33: Service And Maintenance Notices

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS APPLIANCE INSTALLATION, SERVICE, Turn off gas and electrical power to the WARRANTY INFORMATION fireplace and allow it to cool before AND MAINTENANCE NOTICES Your gas appliance is covered by a limited cleaning or servicing the appliance.
  • Page 34 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS GENERAL INFORMATION Gas Pressure Requirements Flame breadth, height and width will diminish 4% for every 1,000 feet of altitude. The fireplace models covered in this manual Tables 2 and 3 show the appliances' gas are direct-vent, sealed combustion gas fire- pressure requirements.
  • Page 35: Appliance Operation And Care

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS OPERATION AND CARE OF YOUR APPLIANCE Appliance Operation To light the appliance refer to the detailed WARNING lighting instructions (see Pages 48 and 49). The appliance lighting instructions may also be Young children should be carefully supervised when they are in the found on the pull out lighting instruction labels attached to the gas control valve.
  • Page 36 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS WARNING Green Wire Connect GTMS (from DFC Fire Hazard. Can cause severe Wire Harness wire harness) injury or death. The receiver Manifold (Out) causes ignition of the appli- Test Port Pressure ance.
  • Page 37 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Key Lock Blue LCD Display Slider Switch In This function will lock the keys to avoid Remote Position unsupervised operation To activate this function, ON/OFF Key press the Mode and Up Arrow keys at the same time.
  • Page 38: Lighting The Appliance

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Lighting the Appliance 16.17 (411 mm) To light electronic appliances refer to the detailed lighting instructions found on Page 48 of these instructions. Instructions can also be found on the pull-out lighting instruction labels attached to the gas control valve.
  • Page 39: Front Glass Enclosure Panel Removal/Installa- Tion

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Front Glass Enclosure Panel Removal Re-install Embers, Volcanic stone and Logs NOTE: Clean glass after first two weeks of operation (after Burn-In period is over) and and Installation Carefully follow placement instructions on then only when necessary and when the Pages 14 and 15).
  • Page 40 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Barrier (see Notice, Page 40) WARNING NOTICE: This fireplace comes with a barrier to reduce the All DRT/DRC6300 Any safety screen or guard likelihood of burns from touching hot glass. If PV Series fireplaces include removed for servicing the appli- the barrier is damaged, the fireplace should be...
  • Page 41 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS INSTALL VOLCANIC STONE, GLOWING EMBERS, AND Cat. No. Model Description LOGS (Traditional Only), or 88L53 Bag of Glowing Embers GLASS MEDIA (Contemporary Only) 80L42 FDVS Bag of Volcanic Stone H8312 Bag of Platinum Embers WARNING...
  • Page 42 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Traditional Only: Log Placement Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate. Figure 60 - Placing Logs 3 and 4 Log Number Description Log, Center...
  • Page 43: Burner Adjustments

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellow-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellow-orange during the first 15 minutes of operation.
  • Page 44: Electronic Appliance Inspection

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Burner Air Shutter Adjustment Procedure Adjustment Electronic Appliance Inspection To light the burner, refer to the lighting To adjust the flame, move the adjustment air WARNING instructions on Page 21. Ensure the igniter shutter (located on the lower venturi) back or lights the pilot.
  • Page 45: Ordering Replacement Parts

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS ORDERING REPLACEMENT PARTS If you encounter any problems or have any PRODUCT REFERENCE INFORMATION questions concerning the installation or ap- plication of this system, please contact your A complete parts list is found at the end of We recommend that you record the important dealer or distributor.
  • Page 46: Accessory Components

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS ACCESSORY COMPONENTS Ceramic and Porcelain Firebox Liners Bag of Glowing Embers Bag of Volcanic Stone The firebox liner kits include ceramic and Bag of Platinum Embers porcelain panels of the side and rear walls. The CLASSIC MISSION ceramic panels have brick-like features in relief.
  • Page 47 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS Dual Arch Screen Kits Classic Screen Kits Log Sets These Dual Arch screen kits can be installed These Screen kits can be installed on the glass This finely crafted log set has detailing that on the glass enclosure panel to help prevent enclosure panel to help prevent direct human replicates the natural look of real wood.
  • Page 48: Lighting Instructions

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. •...
  • Page 49 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 50: Maintenance Schedule

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS MAINTENANCE SCHEDULE Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Annually (Before the onset of the Burning Season) MAINTENANCE TASK PERFORMED BY PROCEDURE...
  • Page 51: Troubleshooting

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS TROUBLESHOOTING GUIDE Electronic Gas Control System NOTE: Service must be performed by a qualified installer, service agency, or your gas supplier. BEFORE TROUBLESHOOTING THE UNIT: 1. Confirm there is power to the unit (fireplace). 2.
  • Page 52 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS TROUBLESHOOTING GUIDE Power Vent System NOTE: Service must be performed by a qualified installer, service agency, or your gas supplier. BEFORE TROUBLESHOOTING THE UNIT: 1. Confirm there is power to the unit (fireplace). 2.
  • Page 53: Replacement Parts List

    INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS REPLACEMENT PARTS LIST 40 in. 45 in. GAS CONTROLS - SIT ELECTRONIC Item Description Catalog Catalog Natural Gas Qty. Qty. Item Description Part No. Qty. Door Modesty Shield H4808 H4809 Gas Valve, SIT...
  • Page 54 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS REPLACEMENT PARTS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 55 INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS INSTALLATION ACCESSORIES Listed Secure Vent Components Listed Secure Vent / Secure Flex Components ® ® Cat. No. Model No. Description Cat. No. Model No. Description 6" (152mm) 77L70 SV4.5L6 Vent Section...
  • Page 56 Innovative Hearth Products General Information Superior DRT/DRC6300 Powervent Series Direct-Vent Gas Fireplaces 900344-00 01/2015 NOTES...
  • Page 57: Year Limited Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 58 Innovative Hearth Products Installation and Operation Instructions Superior DRT/DRC6300 Powervent Series Direct-Vent Gas Fireplaces 900344-00 01/2015 Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number...

This manual is also suitable for:

Drc6340tynDrt6345tynDrc6345tyn

Table of Contents