Superior DRC3035DEN Installation And Operation Instructions Manual

Direct-vent gas fireplacesdrt3000 and drc3000 series

Advertisement

P/N 900285-00 Rev. E 05/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900285-02.
P900285-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Superior
Fireplaces
Models
PFS
DRT3033xxx*
®
C
US
* "xxx" indicates unique model identifiers.
Report No. F13-094
This manual covers all Superior
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
— L'installation et l'entretien doivent être assurés par
DRT3000 and DRC3000 Series Direct-Vent Gas
TM
DRT3035xxx*
DRT3040xxx*
DRC3035DEN
DRC3040DEN
DRT3000 and DRC3000 models.
TM
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT3045xxx*

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRC3035DEN

  • Page 1 Numéro de la pièce 900285-02. DRC3035DEN DRC3040DEN * “xxx” indicates unique model identifiers. Report No. F13-094 This manual covers all Superior DRT3000 and DRC3000 models. P900285-00 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2 Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Space Reserved Contemporary Image THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: General Information

    Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 GENERAL INFORMATION IMPORTANT SAFETY INFORMATION L’information de sûreté importante Información importante de seguridad WARNING AVERTISSEMENT ADVERTENCIA Do not operate appliance with the Ne pas utiliser l’appareil si le...
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 FIREPLACE INSTALLATION, OPERATION, AND MAINTENANCE NOTICES DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION, AND LISTINGS OF THIS UNIT.
  • Page 7 Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 WARNING Clothing or other flammable material should not be placed on or near the appliance. AVERTISSEMENT On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
  • Page 8: Packaging

    Innovative Hearth Products General Information Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels) •...
  • Page 9 11,000 40” Models 20,000 14,000 19,000 14,000† 45” Models 21,500 13,500 21,500 13,500 † 12,000 in Superior Contemporary Models Table 2: Thermal Efficiency (%) Millivolt Electronic Model AFUE * P4 ** AFUE * P4 ** 33” Models 35” Models 40” Models 45”...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 7: Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in (Figure 6). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 6).
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Figure 6: Combustible Side Clearances Figure 7: Mantel Height At 6” minimum side wall clearance, a At 6 in. minimum Mantel depth side wall clearance, Mantel depth combustible...
  • Page 16: Installation Sequence

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 17 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 10: Fireplace Framing Specifications Model Framing NOTE: Dimension “D” is the construction to be 10 1/2 required framing depth when 33 3/4 34 1/4 36 7/8 14 1/2 19 5/8 2 x 4, or larger.
  • Page 18: Route The Gas Supply Line To The Fireplace

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8).
  • Page 19 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove all insulation packing and flue plug block off from rear venting and proceed with fireplace installation.
  • Page 20 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing Non-Combustible Fireboard Standoff in 35” and 40” Contemporary Fireplaces A non-combustible standoff board is provided for 35” and 40” Contemporary fireplaces to prevent overlap of drywall or other material of portions of the fireplace that may be prone to the buildup of heat.
  • Page 21 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper.
  • Page 22 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. U-Shaped Vent 2. If necessary, assemble the vent restrictor and wing as detailed in Figure 12 and Figure 15.
  • Page 23 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required.
  • Page 24 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Vent section length table Table 15 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1 1/2” shorter.
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (25 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 45) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
  • Page 26 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Page 23 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape.
  • Page 28 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 29 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 17: Top Vent—Two 90° Elbows Table 18: Rear Vent—Three Elbows Table 19: Top Vent—Three Elbows When using Secure Flex , use ® Ceiling ceiling firestop/ firestop/spacer spacer SF4.5VF.
  • Page 30 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 slightly elevated plane. The recommended incline is approximately 1/4” per 1 ft (20 mm per 1 m) horizontal, in a direction away from the fireplace. Smaller rise per foot run ratios are acceptable all the way to at or near level.
  • Page 32 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Figure 26: Installing the Horizontal Termination NOTE: To help minimize water infiltration install the firestop/spacer (SV4.5HF) on the exterior side of the wall. The firestop may be caulked with mill base caulk (such as 10K81) or high-temperature silicone.
  • Page 33 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 20: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6–9 1/4” (152–235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 23: Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Ceiling Min.
  • Page 35 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 26: Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Wall firestop/spacer feet meters feet meters feet meters Wall Firestop/Spacer SV4.5HF ** SV4.5HF** 1.524 0.610...
  • Page 36 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Vertical or Horizontal Venting Using Secure Flex Kits and Components Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5)
  • Page 37: Complete The Field Wiring

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent.
  • Page 38 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment.
  • Page 39: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 6. If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall near the fireplace. 7. If an optional control is to be used, wire it in the low voltage circuit (Figure 31).
  • Page 40: Connect The Gas Line

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Figure 32: Junction Box Wiring, 120 V, 60 hz, 1 phase Figure 33: Wiring Diagram— Millivolt Gas Valves Wall-mounted ON/ OFF blower switch THERMOPILE APPLIANCE- MOUNTED or variable speed...
  • Page 41: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation.
  • Page 42: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Optional: Install the Firebox Liners 1. See Page 57 for instructions on Traditional Only: Installing the Firebox Liners. Install the Logs, Volcanic Stone, and Glowing Embers or Glass Media in Contemporary Fireplaces 1.
  • Page 43: Install The Hood

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 28: Air Shutter Adjustment Guidelines Figure 38: Air Shutter Adjustment Rod Amount of Primary Adjustment Flame Color Air Shutter Adjustment Set-Screw If air shutter is Flame will...
  • Page 44: Install The Finishing Materials

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 NOTE: To install the hood after installing the non-combustible finish material over the black surface above the fireplace opening, the bottom edge of the finish material must be 5/8” above the top edge of the hood to allow clearance for installation and removal of the hood.
  • Page 45 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing Facade Step 1. Slide top trim pieces over flange of panel until seated squarely. Step 2. Slide side trim pieces into place (top will overlap slightly). Repeat Step 1 and Step 2 for bottom and opposite side trim for panel.
  • Page 46 Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Step 4a. Slide the foot tabs of the facade base into the slots (see Figure Step 4b. Tilting the facade base up on its foot tabs, secure the top by 41) on both sides near the bottom of the fireplace opening.
  • Page 47: Attach The Safety-In-Operation Warnings

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 48: Installation Accessories

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 INSTALLATION ACCESSORIES Table 30: Listed Secure Vent Components ® 77L78 SV4.5F Flat Roof Flashing Horizontal Square Termination H1968 SV4.5HT-2 with Firestop/Spacer (H2246), 77L79 SV4.5FA 1/12 to 7/12 Adjustable Flashing...
  • Page 49: Gas Conversion Kits

    Innovative Hearth Products Installation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 30: Listed Secure Vent Components ® Mill-Pac, Black, High- 96K93 SV4.5SU Support Strap 10K81 SFMP Temperature Sealant Mill-Pac, Black, High- Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 89L40...
  • Page 50 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 51 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 52 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Figure 43: Millivolt Pilot Figure 44: Orifice Pilot Pilot Orifice Orifice 12. Use pipe joint compound or Teflon tape on all pipe fittings before installing. ® NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds on flare fittings.
  • Page 53 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Conversion Instructions Contemporary Models To convert contemporary fireplaces for another gas, the following components are effected - main orifice, low- rate orifice, regulator setting and pilot setting. Step 1. Remove Burner assembly and replace the main Step 2.
  • Page 54: Operation

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 55 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 56 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 57 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 If the millivolt fireplace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the fireplace main burner can be turned ON/OFF using the optional switch.
  • Page 58 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing the logs, volcanic stone, and glowing embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been competely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 59 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 NOTE: Installing the 33” and 35” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 60 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing the 40” and 45” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 61 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 62 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
  • Page 63: Maintenance

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 MAINTENANCE Refer to the Maintenance Schedule on Page 65 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 64 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 65 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 40: Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By...
  • Page 66: Accessory Components

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 ACCESSORY COMPONENTS (CTD.) Forced Air Kits The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation. The FBK-250 offers variable speed control and a heat-activated switch;...
  • Page 67 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Termination Guard Kits The vent termination guards may be used to minimize exposure to the hot surface of the termination. Table 47: Termination Guard Kits Catalog Model Description...
  • Page 68 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 ON/OFF and Timer Control Kits Feature a timed ON/OFF mode as well as manual ON/OFF operation. Table 49: ON/OFF and Timer Control Kits G-Fire, Cost Effective Solution Catalog Number •...
  • Page 69 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK-100 blower kit is installed. Table 52: Variable Speed Wall Switch Kit...
  • Page 70: Lighting Instructions

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 LIGHTING INSTRUCTIONS Millivolt Gas Valve FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 71 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 72 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Electronic Gas Valve FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 73 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 74 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Electronic Gas Valve (Contemporary Fireplaces) FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 75 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 76: Troubleshooting

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 77 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Table 55: Troubleshooting Electronic Systems 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fireplace is Operate the fireplace from the wall plate switch.
  • Page 78: Replacement Parts

    Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 REPLACEMENT PARTS Table 56: Installer Replacement Parts 33” Models 35” Models 40” Models 45” Models Description Catalog Catalog Catalog Catalog Number Number Number Number Electronic Pilot Assembly, Natural Gas...
  • Page 79 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Wire harness 15’ Skytech BLD J7932 J7932 V-wire Skytech J7933 J7933 Regulator maxitrol J7934 J7934 Pilot Assembly Skytech J7935 J7935 Valve Single outlet Copreci J7936 J7936 Control module Skytech BLD...
  • Page 80 Innovative Hearth Products Operation Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Figure 59: Replacement Parts WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 81: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 82 Innovative Hearth Products Installation and Operation Instructions Superior DRT/C3000 Series Direct-Vent Gas Fireplaces 900285-00 05/2015 Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. SuperiorFireplaces.us.com Record the following important information about your fireplace:...

Table of Contents