Superior DRC3035DEN Installation And Operation Instructions Manual page 32

Direct-vent gas fireplacesdrt3000 and drc3000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT/C3000 Series Direct-Vent Gas Fireplaces
TM
Figure 26: Installing the Horizontal Termination
NOTE: To help minimize water infiltration install the firestop/spacer (SV4.5HF) on the exterior side of the wall. The
firestop may be caulked with mill base caulk (such as 10K81) or high-temperature silicone.
Figure 27: Venting Connection and Exterior Wall Recessing of the Horizontal Termination
32
*Use silicone caulking to
seal the top and sides of
the termination, up to the
underlayment, stucco, or
masonry wall surface.
Maximum Extent of
Vent Run Sections
Siding
Relative to Exterior
*Caulk
Surface of Framing
Last Vent Section. Use
T e l e s c o p i c
Section (SV4.5LA), If
Necessary
*Caulk
SV4.5HT-2
Square Termination
Shown
Stucco
** For thicknesses greater
than 10" (254 mm) see
Table 21.
Interior Surface of
Finished Wall
V e n t
Adapter
SV4.5RCH
900285-00 05/2015
Maximum wall thickness
9 1/4" (235 mm)**
Exterior Surface of Siding
Exterior Surface of
Framing
6 in. to 9 1/4"
(152 to 235 mm)**
SV4.5HT-2
Square Termination
Shown
1-1/4"
Maximum Recess of
the Square Termination into
Exterior Finishing Material
Installation