Superior DRC3035DEN Installation And Operation Instructions Manual page 52

Direct-vent gas fireplacesdrt3000 and drc3000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT/C3000 Series Direct-Vent Gas Fireplaces
TM
Figure 43: Millivolt Pilot
12. Use pipe joint compound or Teflon
13. Retrieve the burner and hold the venturi tube above the orifice. Place the shutter adjusting rod in the slot of the
14. Reinstall the baffle with the two baffle securing screws.
15. Reassemble the remaining components.
16. Turn on gas supply and test for gas leaks (Page 41).
17. Relight the main burner. The lighting instructions can be found on the lighting label in the control compartment
18. Inspect the pilot system for proper flame. The pilot flame should engulf the flame sensor (Figure 36 and
19. Using a manometer, test the inlet and manifold gas pressures (Table 3 and Table 4).
NOTE: Always test pressures with the valve regulator control at the highest setting.
52
Pilot
Pilot
Orifice
Orifice
NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds
on flare fittings.
shutter arm (Figure 38). Set the burner assembly into its position and secure the trapezoidal plate with the two
screws previously removed.
or Page 70. Verify proper burner ignition and operation (Page 42).
Figure 37).
Figure 44: Orifice
tape on all pipe fittings before installing.
®
Operation
900285-00 05/2015

Advertisement

Table of Contents
loading

Table of Contents