Superior DRC3035DEN Installation And Operation Instructions Manual page 33

Direct-vent gas fireplacesdrt3000 and drc3000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT/C3000 Series Direct-Vent Gas Fireplaces
TM
Table 20: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits
Termination Kit and 6" Vent Section (SV4.5L6)
Termination Kit and 12" Vent Section (SV4.5L12)
Termination Kit and Telescopic Section (SV4.5L12)
Horizontal Vent Figures/Tables
NOTE: Secure Vent
terminal may also be used.
NOTE: Two (2) 45° elbows may be used in place of one (1) 90° elbow. The same rise to run ratios, as shown in the
venting figures for 90° elbows, must be followed if 45° elbows are used.
NOTE: Maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane. The recommended incline
is approximately 1/4" per 1 ft (20 mm per 1 m) horizontal, in a direction away from the fireplace. Smaller rise per
foot run ratios are acceptable all the way to at or near level. Use a carpenter's level to measure from a constant
surface and adjust the support straps as necessary.
NOTE: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) firestop/spacer must be used any time vent pipe passes
through a combustible floor or ceiling. SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) firestop/spacer must be used
any time vent pipe passes through a combustible wall.
Do not join separate sections of concentric flexible vent together.
Table 21: Rear Vent—No Elbows
See Table 21 as an aid in venting component selection for a
particular range of exterior wall thicknesses.
Note: "H" is horizontal distance from rear of unit to outer wall
surface
NOTE: When venting Rear Horizontal with slip collar and
termination only, install base vent restrictor with the
breakaway portion raised.
Table 22: Top Vent—One 90° Elbow, Elbow Connection at Fireplace
feet
3
Install the U-shaped vent restrictor in any vent run with
more than 4 ft of vertical rise. See Page 22 for more
information.
See Table 20 as an aid in venting component selection for a
particular range of exterior wall thicknesses.
NOTE: Only in top vent where elbow is connected at fireplace collar
is it allowed to count elbow as 1 ft. vertical (V) rise.
Vent Components Required
Termination Kit Only
rigid vent pipe and terminal are shown in the figures. Secure Flex
®
H Maximum
V Minimum
meters
feet
0.91
Elbow only
Exterior Wall Thickness
6–9 1/4" (152–235 mm)
10 3/4–14" (273–356 mm)
16 3/4–20" (426–508 mm)
11 3/4–20" (299–508 mm)
WARNING
H = 28 in. (711 mm) Maximum
H = 21" (533 mm) maximum
28"
(711 mm) to outside
of termination
*
When using Secure Flex
wall firestop/spacer SF4.5HF.
meters
900285-00 05/2015
flexible vent pipe and
®
**When using Secure Flex, use
Wall Firestop/Spacer SF4.5HF.
, use
®
H
Wall
firestop/
spacer
SV4.5HF *
Installation