Prepare the Fireplace Top Spacers
2.
1. The two (2) 4" standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to
2. Bend the standoffs as shown (Figure 9):
3. Align the hole in the standoff with the hole in the fireplace top, and secure with the screw that was removed in
Figure 8: Unassembled standoff
Screw

Route the Gas Supply Line to the Fireplace

3.
1. Route a 1/2" (13 mm) gas line to the left side of the fireplace (Figure 10).
NOTE: Gas lines must be routed, assembled, and made of materials that are in strict accordance with local codes
and regulations. All fireplaces are factory-equipped with a flexible gas line connector and a 1/2" shutoff valve
(Page 40).
Figure 10: Routing the gas line - 35", 40",
Proper Sizing of Gas Line
Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed
per requirements outlined in the National Fuel Gas Code, NFPA 54—latest edition (USA) or CAN/CGA-B149.1—
latest edition (Canada).
The gas supply line should not be connected to the appliance until step 14. Connect the Gas Line (Page 40).
NOTE:
If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this
is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
This can result in insufficient fuel delivery that can cause sooting, delayed ignition, or other
malfunctions. Any damage resulting from an improper installation is not covered by the
limited warranty.
18
the detached end (Figure 8).
Step 1 (Figure 9).
Positioned flat as shipped from the factory
Top Standoff
Fireplace Front
45" Models
Left side front corner of
fireplace framing
Pipe coupling
(recommended)
7 5/8"
(195 mm)
3"
(76 mm)
All fireplaces are factory-equipped with a flexible gas line connector and 1/2" shutoff valve (Figure 35).
See Massachusetts Horizontal Vent Requirements for additional requirements for installations in the state of
Massachusetts in the USA.
A pipe joint compound rated for gas should be used on the threaded joints. Ensure propane-resistant
compounds are used in propane applications. Be very careful that the pipe compound does not get inside
the pipe.
A sediment trap in the supply line as close as possible to the fireplace is recommended.
Check with the local building official for local code requirements (e.g., Are below grade penetrations of the gas
line allowed?, etc).
Figure 9: Assembled standoffs
Configuration for 1/2" finish materials
Top Standoff
Fireplace
Front
Figure10a: Routing the Gas Line - 33" Model
Figure 60: Routing the gas line
Left side front corner of
fireplace framing
Pipe coupling
(recommended)
3"
(76 mm)
CAUTION
900285-00 05/2015
Configuration for 5/8" finish materials
Top Standoff
5 1/4"
(140 mm)
Installation