Superior DRT63STTEN Installation And Operation Instructions Manual

Drt63st see-through direct-vent gas fireplaces
Table of Contents

Advertisement

P/N 900355-01 Rev. A 07/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900355-03.
P900355-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicat-
ed on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRT63ST See-Through Direct-Vent Gas Fireplaces
Models
PFS
®
C
US
Report No. F14-107
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consulta-
tion ultérieure.
DRT63STTEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT63STTEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRT63STTEN

  • Page 1 P/N 900355-01 Rev. A 07/2015 Models Ce manuel est disponible en francais, simplement ® en faire la demande. Numéro de la pièce 900355-03. DRT63STTEN DRT63STTEP Report No. F14-107 P900355-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2: General Information

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTREMELY HOT!
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Traditional Fireplace THANk YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR bUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Appliance Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or prop- erty damage. Refer to this manual. For assistance or additional information consult a quali- fied installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these ap- pliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be danger- ous.
  • Page 8: Packaging

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 PACkAGING GENERAL INFORMATION Inputs and Efficiencies The assembled vented gas fireplace is pack- Appliance BTU inputs are listed in Table 1A. Approved Vent Components aged with the following items: Appliance efficiencies are listed in Table 1B.
  • Page 9: Gas Valve Diagram

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Install the appliance according to the regulations Gas Valve Diagram The appliance and its appliance main of the local authorities having jurisdiction and, gas valve must be disconnected from See valve diagram (Figure 1).
  • Page 10: Cold Climate Insulation

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 COLD CLIMATE INSULATION For cold climate installations, seal all cracks Outdoors around the appliance with noncombustible material and wherever cold air could enter the Indoors room. If the floor is above ground level, it is (Top View) especially important to insulate outside chase cavity between studs and under the floor on...
  • Page 11: Vent Termination Clearances

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 VENT TERMINATION TERMINATION HEIGHTS FOR VENTS ABOVE Vent/air intake termination clearances FLAT OR SLOPED ROOFS CLEARANCES above the high side of an angled roof Horizontal Overhang are listed in the table below. These instructions should be used as a guide- 2 FT line and do not supersede local codes in any...
  • Page 12 Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 NOTE: Exterior wall • Local codes or regulations may require different clearances. • Location of vent termination must NOT = Vent terminal 36" interfere with access to electrical service. = Area terminal NOT permitted (91.4 cm) Center Line of...
  • Page 13: Hearth Extensions (Optional)

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 HEARTH EXTENSIONS (OPTIONAL) Optional Outdoor Hearth Extension NOTE: Hearth extensions are not required with this appliance. All outdoor hearth material (combustible and non-combustible) must be installed a minimum of 6" (152 mm) below the base of the fireplace (see Figure 8 ).
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 MINIMUM CLEARANCES TO COMbUSTIbLES Do NOT insulate space between Appliance and Vent Clearances appliance and area above it. The appliance is approved with zero clearance to combustible materials Combustible Enclosure/Shelf on both sides (as detailed in Table 5), with the following exceptions: Min.
  • Page 15: Pre-Installation Steps

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 PRE-INSTALLATION STEPS TYPICAL INSTALLATION SE- DETAILED INSTALLATION STEPS QUENCE The appliance is shipped with all gas controls Step 1. FRAMING and components installed and pre-wired. The typical sequence of installation is outlined Frame these appliances as illustrated in Figure below.
  • Page 16: Framing Specifications

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 FRAMING SPECIFICATIONS Framing should be constructions of 2x4 or larger lumber.    52-1/8 47-3/8 75-1/2 26-3/8 (mm) (1324) (1203) (1918) (670) (152)  Dimension b is from fireplace base to top framing member. ...
  • Page 17: Fireplace Dimensions

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 FIREPLACE DIMENSIONS (shown with Outdoor Kit installed) FIREPLACE COLLAR AND VENT SIZE Fireplace Vent Collar and Vent Pipe (Coaxial DV) 8" Inner / 11" Outer NOTE: All venting/termination systems (vertical and horizontal) require installation of the provided Vent Restrictor.
  • Page 18: Step 2. Route Gas Line

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Step 2. ROUTE GAS LINE Proper Sizing of Gas Line NOTES: • All appliances are factory-equipped with a Properly size and route the gas supply line NOTICE flexible gas line connector and 1/2" shutoff from the supply regulator to the area where the valve (see Figure 37 on Page 29).
  • Page 19: Step 3. Install Vent System

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Step 3. INSTALL VENT SYSTEM The vent system may not service multiple ap- NOTE: When possible, install the vent pliances and must never be connected to a flue restrictor through the top of the appliance serving a solid fuel burning appliance.
  • Page 20: Vertical (Roof) Termination

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Vertical (Roof) Termination Systems This section includes configurations for verti- i t c i t c O O O O O T T T T T cal (roof) termination systems with either A A A A A i t c i t c...
  • Page 21: Vertical Venting

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Vertical Termination System b. Attach vent components to appliance. D. Install firestop/spacer at ceiling. with Offset Vertical Venting Secure Vent® SV8 direct-vent system com- When using Secure Vent, use SV8BF firestop/ ponents are unitized concentric pipe compo- NOTE: If not already done, install the spacer at ceiling joists.
  • Page 22 Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Vertical Termination System H. Frame roof opening. k. Install vertical termination. The final step involves installation of the verti- Identify location for vent at the roof. Cut and/ with Offset Vertical Venting (continued) cal termination.
  • Page 23: Vertical Termination System Figures And Tables

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 VERTICAL TERMINATION SYSTEM Vertical Termination System with Offset Vertical Venting using Two 90-Degree Elbows FIGURES AND TAbLES Secure Vent rigid vent pipe and termination ® components are shown in the figures. NOTE: Two 45-degree elbows may be used in place of one 90-degree elbow.
  • Page 24: Horizontal (Wall) Termination

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Horizontal (wall) Termination Horizontal Termination System with Horizontal/Inclined Run Systems Support building This section includes configurations for hori- Horizontal / Inclined Run brackets Support Termination zontal venting systems with horizonal termina- Framing (SV8HTS4) tion (terminates through an outside wall) (see...
  • Page 25 Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 It is important to maintain the required clear- ances to combustibles: 1" (25 mm) at all sides To help minimize water infiltration for all vertical runs; and 4" (102 mm) at the it is recommended that the Fire- top, 1"...
  • Page 26: Horizontal Termination System Figures And Tables

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 See Table 8 as an aid in venting component selection for a HORIZONTAL TERMINATION SYSTEM FIGURES/TAbLES particular range of exterior wall thicknesses. Note: • Secure Vent rigid vent pipe and termination components are shown ®...
  • Page 27 Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 HORIZONTAL VENT FIGURES/TAbLES (continued) HORIZONTAL TERMINATION SYSTEM WITH HORIZONTAL/INCLINED RUN USING TWO 90-DEGREE ELbOWS (Elbow connection not directly at appliance) NOTE: The provided vent restrictor is required in all venting systems. See Page 16 for settings.
  • Page 28: Step 4. Field Wiring

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Step 4. FIELD WIRING Electronic Wiring 4. Connect the black power supply wire to the power outlet’s red pigtail lead and the white (See Figures 35 and 36) power supply wire to the common terminal CAUTION: Label all wires prior to discon- Note: The electronic appliance must be of the outlet as shown in Figures 35 and 36.
  • Page 29: Step 5. Remove Glass Door

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Step 5. REMOVE bARRIER AND Step 6. CONNECT GAS LINE GLASS DOOR ASSEMBLY (ON Right Side All codes require a shut-off valve mounted in the Modesty Panel CONTROL SIDE) supply line.
  • Page 30: Step 7. Install Firebox Liner Panels

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Step 7. INSTALL FIREbOX Step 9. VERIFY APPLIANCE PILOT ASSEMbLY LINER PANELS OPERATION Proper Pilot Flame Appearance Install the ceramic or porcelain firebox liner Turn on the burner, then observe the individual Igniter tongues of flame on the burner.
  • Page 31: Step 12. Burner Adjustments

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 burner Air Shutter Adjustment Step 12. bURNER ADJUSTMENTS 1. Light the appliance (follow lighting proce- dure in Care and Operation Instructions or Procedure on lighting label in control compartment). Flame Appearance and Sooting 2.
  • Page 32: Finishing Requirements

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 FINISHING REQUIREMENTS wall Details - INDOOR SIDE(S) Wall Details - OUTDOOR SIDE IMPORTANT! Complete the finished interior wall. To install the appliance Complete finished exterior wall per the instructions provided Min.
  • Page 33 Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Overhang Combustible Sheathing Non-Combustible Board Siding Siding Siding Trim Combustible Sheathing Exterior Minimum Clearances Material Sheathing Requirements Vinyl 12” (305 mm) 35-1/2” (902 mm) 6” (305 mm) Non-Vinyl 7” (178 mm) 35-1/2”...
  • Page 34: Step 13. Attaching Safety-In-Operation

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 STEP 13. INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 35: Installation Accessories

    Innovative Hearth Products Installation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 INSTALLATION ACCESSORIES Listed Secure Vent Components ® Cat. Model Description Cat. Model Description H2262 SV8SU Support Strap H8323 SV8HTS4 Horizontal Square Termination with Firestop/Spacer (H8322) and Adaptor (H2267) H2263 SV8SP Support Plate H3908...
  • Page 36: Operation And Care Of Your Appliance

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 OPERATION AND CARE OF YOUR APPLIANCE Familiarize yourself with the gas control valve that your appliance uses. See Pages 8 and 9 for gas valve infromation and specifications. WARNING To light the appliance refer to the detailed Young children should be carefully supervised when they are in the lighting instructions (see Pages 50 and 21).
  • Page 37: Homeowner - Attaching Safety-In-Operation Warnings

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES à COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD ATTACHING SAFETY IN OPERATION WARN- LA SÉCURITÉ D’UTILISATION EN OPERACIóN INGS Votre foyer a été...
  • Page 38: Remote Control System

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Remote Control System Low Battery Power Detection Temperature Indicator Display With the system in the "OFF" position, press The Remote and Receiver allows you to com- The life span of the Receiver batteries depends the Room Temperature Key and the Mode Key mand the functions of your fireplace from the on various factors: quality of the batteries used,...
  • Page 39 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 key Lock Slider Switch In blue LCD Display This function will lock the keys to avoid unsu- Remote Position pervised operation To activate this function, press the MODE and UP keys at the same time. ON/OFF key To de-activate this function, press MODE and ROOM...
  • Page 40: Maintenance

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Clean Logs and burner MAINTENANCE operation (after burn-in period is over) and then only when necessary and ONLY WHEN Carefully remove the logs (use care when han- (See Maintenance Schedule, Page 52) THE APPLIANCE IS COOL.
  • Page 41: Removal/Installation Of Glass Doors Barriers And Modesty Panel

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Removing Glass Doors, Barrier and REMOVAL AND INSTALLATION OF WARNING Modesty Panel GLASS DOORS, BARRIERS AND MOD- (see Figure 54) ESTY PANEL Do not operate appliance with the glass front removed, cracked WARNING barrier (see Notice, Page 30) - This fireplace or broken.
  • Page 42: Placement Of Volcanic Stone, Glowing Embers, And Logs

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 PLACEMENT OF VOLCANIC STONE, GLOwING EMBERS, Bag of Glowing Embers AND LOGS 1. Remove modesty panel, and glass door assembly from one side of fireplace (see Page 41). 2. Locate materials (log set, bag of glowing embers, and bags of volca- nic stone).
  • Page 43 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 5. Install logs (reference Figure 58 and Table 9). 6. Place rectangular notches on underside of Center Log A (Figure 60 ) over Boss #1 and Boss #4 (Figure 59 ). Note: Logs are FRAGILE! Handle with care to prevent breakage.
  • Page 44 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 9. Place groove on underside of Top Right Log D over the grate as 11. See Figure 65. Place groove on underside of Top Front Log F over shown in Figure 63. the grate finger.
  • Page 45: Burner Adjustments

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 bURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame that is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish-orange during the first 30 minutes of operation.
  • Page 46: Burner Air Shutter Adjustment Procedure

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Electronic Appliance Checkout burner Air Shutter Adjustment Procedure 1. Light the appliance (follow lighting proce- dure in Care and Operation Instructions or To light the burner, refer to the lighting instruc- on lighting label in control compartment).
  • Page 47: Ordering Replacement Parts

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 ORDERING REPLACEMENT PARTS If you encounter any problems or have any Please call Innovative Hearth Products for questions concerning the installation or ap- the phone number of your nearest IHP dealer, A complete parts list is found at the end of plication of this system, please contact your who will answer your questions or address...
  • Page 48: Accessory Components

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 ACCESSORY COMPONENTS Ceramic and Porcelain Panel kits The panel kits include ceramic and porcelain panels for the side walls. Andiron kits The ceramic panels have brick-like features in relief. The andiron kits include two andirons for one side.
  • Page 49 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 ACCESSORY COMPONENTS Classic Screen kits Screen Panel kits (continued) These decorative freestanding firescreen pan- These screen kits create a barrier to prevent di- els are designed to enhance the beauty of the rect contact with the hot glass.
  • Page 50: Operating (Lighting) Instructions

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. •...
  • Page 51 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. •...
  • Page 52: Maintenance Schedule

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 MAINTENANCE SCHEDULE WARNING: bURN HAZARD. Turn OFF gas and electrical power to the fireplace, and allow it to cool before cleaning or servicing the appliance. Annually (before onset of burning season) MAINTENANCE TASk ACCOMPLISHING PERSON PROCEDURE...
  • Page 53: Troubleshooting Guide

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 TROUbLESHOOTING THE FIREPLACE NOTE: Before troubleshooting the gas control system, make sure the external gas shutoff valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIbLE CAUSES CORRECTIVE ACTION...
  • Page 54: Replacement Parts List

    Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 REPLACEMENT PARTS LIST Contact an Innovative Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. Item Gas Controls - SIT Electronic Description...
  • Page 55 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 REPLACEMENT PARTS ILLUSTRATION Circled numbers correspond to “Replacement Parts List” on previous page. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 56 Innovative Hearth Products Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 57: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 58 Innovative Hearth Products Installation and Operation Instructions DRT63ST Direct-Vent Gas Fireplaces 900355-01, 07/2015 Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. SuperiorFireplace.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed...

This manual is also suitable for:

Drt63sttep

Table of Contents