Wall Finishes / Surrounds / Mantels; Installation Preparation - Superior DRC3035DEN Installation And Operation Instructions Manual

Direct-vent gas fireplacesdrt3000 and drc3000 series
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT/C3000 Series Direct-Vent Gas Fireplaces
TM
Figure 6: Combustible Side Clearances
At 6" minimum
side wall
clearance, a
At 6 in. minimum
side wall clearance,
combustible
Top View of
Top View of
a combustible wall
wall can project
Fireplace
Fireplace
can project to any
to any length.
length.
Combustible materials
Combustible Materials
o
o
45
45
allowed in shaded area
3 1/2"
Allowed In Shaded Area
3 1/2 in.
"Safe Zone"
"Safe Zone".
(89 mm)*
(89 mm)
Combustible Walls
Combustible walls
shown in dark gray
shown in dark gray
Combustible mantel legs may
Combustible mantel
project beyond either side
legs may project
of the fireplace opening
beyond either side of
as long as they are kept
the fireplace opening
within the shaded area
as long as they are kept
illustrated here.
within the shaded area
illustrated here.
6"
6 in.
(152 mm)
(152 mm)
* 6" (152 mm) in 35" and 40" Contemporary units

Wall Finishes / Surrounds / Mantels

NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined
by the fireplace front face (black sheet metal). Never allow combustible materials to be positioned in front of or
overlapping the fireplace face (Figure 40).
Non-combustible materials, such as surrounds and other fireplace trim, may be installed on the fireplace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels
constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do
not allow anything to hang below the fireplace hood.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above
the fireplace.
NOTE: To avoid heat-related finish damage, use finish materials rated 175 °F, or higher, on the underside of the mantel.

INSTALLATION PREPARATION

The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction).
2. Remove the shipping pad, exposing the front glass door.
3. Remove the glass door (Page 61).
NOTE: Place the glass door on the shipping carton to protect its surface.
Figure 7: Mantel Height
Mantel depth
20 (508)
18 (457)
16 (406)
14 (356)
12 (305)
10 (254)
4
8
12
(102)
(203)
(305)
10
6
2
(254)
(152)
(51)
in. (mm)
Traditional
25 (635)
23 (584)
21 (533)
19 (483)
17 (432)
15 (381)
Hood
12
(305)
10
(254)
Fireplace
Contemporary
Installation
900285-00 05/2015
Mantel depth
4
8
Fireplace
(102)
(203)
6
Opening
2
(152)
(51)
Fireplace
15