Set Temperature Correction - Toshiba RAS-M10PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
18. Set temperature
Indoor Control P.C. Board (Factory Default)
correction
DB01
In HEAT Operation
¡
: With Jumper wire
×
: Cut Jumper wire
L01
C03
T101
Jumper wire setup
J804
J805
×
×
¡
×
¡
×
¡
¡
1. Purpose
When the difference between the set temp.
of the remote controller and the room temp.
Jumper wire
J804
is wide due to the installation condition, etc,
J805
the set temp. is corrected.
J806
(HEAT operation only)
J807
2. Description
IC801
The set temp. received from the remote
controller is corrected.
J804
The correct value from –2°C to +4°C is
J805
changed by the jumper wire on P.C. board of
J806
J807
the indoor microcomputer.
HEAT
shift value
–2
+4
+2
← At shipment
0
– 70 –