Toshiba RAS-M10PKVP-E Service Manual page 44

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Outdoor Unit : RAS-4M27GAV-E1
<Heating>
Temperature
No. of
condition
operating
units
Indoor
Outdoor
1 unit
2 units
3 units
20 / –
7 / 6
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor themometer)
2. Connecting piping condition : 5 meters × 4 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MPa)
07
2.1 to 2.3
10
2.7 to 2.9
13
3.2 to 3.4
16
3.6 to 3.9
18
3.6 to 3.9
07
07
2.6 to 2.8
10
07
2.6 to 2.8
13
07
2.7 to 2.9
16
07
2.8 to 3.0
18
07
2.9 to 3.1
10
10
2.7 to 2.9
13
10
2.8 to 3.0
16
10
2.9 to 3.1
18
10
2.9 to 3.1
13
13
2.9 to 3.1
16
13
3.0 to 3.2
18
13
3.0 to 3.2
16
16
3.1 to 3.3
18
16
3.1 to 3.3
18
18
3.1 to 3.3
07
07
07
2.3 to 2.5
10
07
07
2.3 to 2.5
13
07
07
2.3 to 2.5
16
07
07
2.3 to 2.5
18
07
07
2.3 to 2.5
10
10
07
2.3 to 2.5
13
10
07
2.3 to 2.5
16
10
07
2.3 to 2.5
18
10
07
2.3 to 2.5
13
13
07
2.3 to 2.5
16
13
07
2.3 to 2.5
18
13
07
2.3 to 2.5
16
16
07
2.3 to 2.5
18
16
07
2.3 to 2.5
10
10
10
2.3 to 2.5
13
10
10
2.3 to 2.5
16
10
10
2.3 to 2.5
18
10
10
2.3 to 2.5
13
13
10
2.3 to 2.5
16
13
10
2.3 to 2.5
18
13
10
2.3 to 2.5
18
16
10
2.3 to 2.5
13
13
13
2.3 to 2.5
16
16
10
2.3 to 2.5
16
13
13
2.5 to 2.7
18
13
13
2.5 to 2.7
16
16
13
2.5 to 2.7
18
16
13
2.5 to 2.7
16
16
16
2.5 to 2.7
– 44 –
Heat exchanger
Indoor
pipe temperature
fan
T1 (°C)
T2 (°C)
36 to 38
3 to 5
High
44 to 46
2 to 4
High
52 to 54
2 to 4
High
53 to 55
2 to 4
High
53 to 55
2 to 4
High
44 to 46
1 to 3
High
44 to 46
1 to 3
High
45 to 47
0 to 2
High
45 to 47
0 to 2
High
46 to 48
0 to 2
High
45 to 47
0 to 2
High
45 to 47
0 to 2
High
46 to 48
0 to 2
High
46 to 48
0 to 2
High
46 to 48
0 to 2
High
47 to 49
–1 to 1
High
47 to 49
–1 to 1
High
48 to 50
–1 to 1
High
48 to 50
–1 to 1
High
48 to 50
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
38 to 40
–1 to 1
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
37 to 39
–2 to 0
High
Compressor
Outdoor
revolution
fan
(rps)
MED
29
MED
41
MED
52
MED
56
MED
60
MED
59
MED
61
MED
64
MED
65
MED
67
MED
62
MED
64
MED
66
MED
66
MED
67
MED
69
MED
70
MED
71
MED
71
MED
71
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
73
MED
73
MED
73
MED
73
MED
73
MED
73
MED
74
MED
74
MED
74
MED
74
MED
74