Toshiba RAS-M10PKVP-E Service Manual page 46

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Outdoor Unit : RAS-3M26GAV-E1
<Cooling>
Temperature
No. of
condition
operating
units
Indoor
Outdoor
1 unit
2 units
3 units
27/19
35/-
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor themometer)
2. Connecting piping condition : 5 meters × 4 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MPa)
07
0.9 to 1.1
10
0.8 to 1.0
13
0.7 to 0.9
16
0.6 to 0.8
18
0.6 to 0.8
07
07
0.9 to 1.1
10
07
0.8 to 1.0
13
07
0.8 to 1.0
16
07
0.8 to 1.0
18
07
0.8 to 1.0
10
10
0.8 to 1.0
13
10
0.8 to 1.0
16
10
0.8 to 1.0
18
10
0.8 to 1.0
13
13
0.8 to 1.0
16
13
0.7 to 0.9
18
13
0.7 to 0.9
16
16
0.7 to 0.9
18
16
0.7 to 0.9
18
18
0.7 to 0.9
07
07
07
0.8 to 1.0
10
07
07
0.8 to 1.0
13
07
07
0.8 to 1.0
16
07
07
0.8 to 1.0
18
07
07
0.8 to 1.0
10
10
07
0.8 to 1.0
13
10
07
0.8 to 1.0
16
10
07
0.8 to 1.0
18
10
07
0.8 to 1.0
13
13
07
0.8 to 1.0
16
13
07
0.8 to 1.0
18
13
07
0.8 to 1.0
16
16
07
0.8 to 1.0
18
16
07
0.8 to 1.0
10
10
10
0.8 to 1.0
13
10
10
0.8 to 1.0
16
10
10
0.8 to 1.0
18
10
10
0.8 to 1.0
13
13
10
0.8 to 1.0
16
13
10
0.8 to 1.0
18
13
10
0.8 to 1.0
18
16
10
0.8 to 1.0
13
13
13
0.8 to 1.0
16
16
10
0.8 to 1.0
16
13
13
0.8 to 1.0
18
13
13
0.8 to 1.0
16
16
13
0.8 to 1.0
– 46 –
Heat exchanger
Indoor
pipe temperature
fan
T1 (°C)
T2 (°C)
11 to 13
44 to 46
High
9 to 11
45 to 47
High
8 to 10
46 to 48
High
7 to 9
47 to 49
High
7 to 9
48 to 50
High
11 to 13
46 to 48
High
10 to 12
47 to 49
High
10 to 12
47 to 49
High
10 to 12
48 to 50
High
10 to 12
49 to 51
High
10 to 12
47 to 49
High
10 to 12
48 to 50
High
10 to 12
49 to 51
High
10 to 12
49 to 51
High
10 to 12
50 to 52
High
9 to 11
51 to 53
High
9 to 11
51 to 53
High
9 to 11
52 to 54
High
9 to 11
52 to 54
High
9 to 11
52 to 54
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
11 to 13
51 to 53
High
Compressor
Outdoor
revolution
fan
(rps)
LOW
16
MED
22
MED
35
MED
45
MED
52
MED
36
MED
39
MED
46
MED
49
MED
52
MED
42
MED
46
MED
50
MED
52
MED
54
MED
58
MED
60
MED
62
MED
62
MED
62
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60
MED
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents