10-3-6. Indoor Unit Installation
1. Pass the pipe through the hole in the wall, and
hook the indoor unit on the installation plate at
the upper hooks.
2. Swing the indoor unit to right and left to confirm
that it is firmly hooked on the installation plate.
3. While pushing the indoor unit onto the wall, hook
it at the lower part on the installation plate.
Pull the indoor unit toward you to confirm that it
is firmly hooked on the installation plate.
4. Pull the connecting cable through the cable slot
on the rear panel so that it protrudes about
15 cm out of the front.
1
2
Hook
Fig. 10-3-19
• For detaching the indoor unit from the installation
plate pull the indoor unit toward you while pushing
the bottom up at the specified places.
Push
Push
Fig. 10-3-20
Hook here
[1] Installation plate
Push (unhook)
– 84 –
10-3-7. Drainage
1. Run the drain hose at a downward sloped angle.
NOTE
• Hole should be made at a slight downward slant
on the outdoor side.
Do not rise the drain hose.
50 mm
or more
Do not put the
drain hose end
into water.
Fig. 10-3-21
2. Put water in the drain pan and make sure that
the water is being drained outside.
3. When connecting extension drain hose, insulate
the connection part of extension drain hose with
shield pipe.
Shield pipe
Drain hose
Inside the room
Fig. 10-3-22
CAUTION
Install the drain pipe for proper drainage.
Improper drainage can result in water dripping
inside the room.
This air conditioner has been designed to drain
water collected from condensation which forms on
the back of the indoor unit, to the drain pan.
Therefore, do not locate the power cord and other
parts at a high place above the drain guide.
Space for
pipes
Fig.
Do not form the drain hose
into the waved shape.
Do not put the drain
hose end in the
drainage ditch.
Extension drain hose
Wall
Drain
guide
10-3-23