Temporary Operation; Air Purifying Control; Purpose - Toshiba RAS-M10PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
11. Temporary
Pushing [RESET] button starts the temporary
operation
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more,
the temporary [COOL] operation is performed.
PURE indicator (Orange) ON
NO
Did you push [RESET] button
for 3 seconds or more?
YES
Did you push [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.

12. Air purifying control

Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Louver swing is available
Air purifying operation
AC + Air purifying operation
Follows to AC operation
NOTE When the previous operation was the operation of air conditioner + air purifier, an operation of air conditioner + air purifier
starts by pushing AC button on the remote controller. (Operation of air conditioner + air purifier is stored in memory.)
Sending air purifier-ON
[1] Air conditioner stops
Operation indicator ON
∗1
PURE indicator ON
Louver Open memory
position (Cooling)
Moving panel Open
Fan ON
Air purifier ON
Air purifying operation
∗1 Fan speed at Fan Auto mode.
YES
Push RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation button
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
All stop
AC operation
All stop
Fan speed *1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
[1], [2]
[2] Air conditioner
operates
PURE indicator ON
Air purifier ON
Air conditioner +
air purifier operation
– 64 –
1) When pushing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, "beep, beep, beep"
sound is heard and [AUTO RESTART]
control is changed.
3) When keeping [RESET] button pushed for
10 seconds or more, "beep" sound is heard
and the temporary [COOL] operation starts.
4) If the filter lamp goes on, push [RESET]
button to go off the filter lamp, and then push
[RESET] button again.
5) To stop the temporary operation, push the
button again.

1. Purpose

This function generates negative ion while
cleaning the air in the room.
The air purifying control function is to alert
the user that something is wrong in the
ionizing or air purifying operation.
If air purifier-ON signal is received while the
air conditioner stops, the air purifier starts
operation, and if it is received while the air
conditioner operates, the air conditioner and
the air purifier start operation.
The air ion generator operates linked with
the air purifying operation.
Sending air purifier-OFF
[3] Air purifier operates
Operation indicator OFF
PURE indicator OFF
Fan OFF
Air purifier OFF
Louver close
All stop
Fan speed level
WC (WF)∗
W7 (WA)∗
0
8
Description
[3], [4]
[4] Air conditioner +
Air Purifier operation
PURE indicator OFF
Air purifier OFF
Air conditioner operates
( )∗ : Hi Power
W5 (W7)∗
W2 (W3)∗
15
30
min

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents