<Heating> (Continued)
Temperature
No. of
condition
operating
units
Indoor
Outdoor
4 units
20 / –
7 / 6
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor themometer)
2. Connecting piping condition : 5 meters × 4 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MPa)
07
07
07
07
2.0 to 2.2
10
07
07
07
2.0 to 2.2
13
07
07
07
2.0 to 2.2
16
07
07
07
2.0 to 2.2
18
07
07
07
2.0 to 2.2
10
10
07
07
2.0 to 2.2
13
10
07
07
2.0 to 2.2
16
10
07
07
2.0 to 2.2
18
10
07
07
2.0 to 2.2
13
13
07
07
2.0 to 2.2
16
13
07
07
2.0 to 2.2
18
13
07
07
2.0 to 2.2
16
16
07
07
2.0 to 2.2
18
16
07
07
2.0 to 2.2
10
10
10
07
2.0 to 2.2
13
10
10
07
2.0 to 2.2
16
10
10
07
2.0 to 2.2
18
10
10
07
2.0 to 2.2
13
13
10
07
2.0 to 2.2
16
13
10
07
2.0 to 2.2
18
13
10
07
2.0 to 2.2
16
16
10
07
2.0 to 2.2
18
16
10
07
2.0 to 2.2
13
13
13
07
2.0 to 2.2
16
13
13
07
2.0 to 2.2
18
13
13
07
2.0 to 2.2
16
16
13
07
2.0 to 2.2
10
10
10
10
2.0 to 2.2
13
10
10
10
2.0 to 2.2
16
10
10
10
2.0 to 2.2
18
10
10
10
2.0 to 2.2
13
13
10
10
2.0 to 2.2
16
13
10
10
2.0 to 2.2
18
13
10
10
2.0 to 2.2
13
13
13
10
2.0 to 2.2
16
13
13
10
2.0 to 2.2
13
13
13
13
2.0 to 2.2
16
16
10
10
2.0 to 2.2
– 45 –
Heat exchanger
Indoor
pipe temperature
fan
T1 (°C)
T2 (°C)
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
33 to 35
–2 to 0
High
Compressor
Outdoor
revolution
fan
(rps)
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
72
MED
73
MED
73
MED
73
MED
73
MED
73
MED
73
MED
74
MED
74
MED
74