Construction Views - Toshiba RAS-M10PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

4-1. Indoor Unit
RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E
RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND
Front panel
Piping port from
62
left/right sides
(Knockout system)
18
Refrigerant pipe
connecting port Gas side
Flare dia. 9.52
(16,18PKVP-E (-ND) :dia. 12.7)
Outside length 0.35m
Installation plate
hanging section
Stud bolt hole
For dia.8 to 10
Minimum
distance to
wall
130 or more
Recommend
180 or more

4. CONSTRUCTION VIEWS

790
Plasma ion charger
790
Air filter
Guard wire
Name Plate
77
Installation plate
hanging section
312
100
590
450
312
Hanging
section
Minimum
distance to
ceiling
Lower part
Lower part
hanging section
hanging section
Center line
of main unit
Shape line
Center line of
installation plate
installation plate
330
790
Moving panel
Piping port from
left/right sides
(Knockout system)
From wall to air outlet length
77
37
Refrigerant pipe
connecting port Liquid side
Flare dia. 6.35
Outside length 0.4m
Drain hose VP16
Outside length 0.54mm
100
Stud bolt hole
For dia.8 to dia.10
Minimum
distance to
wall
130 or more
Recommend
180 or more
330
– 35 –
(At the time of operation)
296.2
(At the time of a stop)
242
62
64
34
4.5
dia.4.2
Remote controller holder
58
19
Wireless remote controller
Heat insulation
(Drain hose detail)
19