Toshiba RAS-M10PKVP-E Service Manual page 43

Split type
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

<Cooling> (Continued)
Temperature
No. of
condition
operating
units
Indoor
Outdoor
4 units
27 / 19
35 / –
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor themometer)
2. Connecting piping condition : 5 meters × 4 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
P (MPa)
07
07
07
07
0.9 to 1.1
10
07
07
07
0.9 to 1.1
13
07
07
07
0.9 to 1.1
16
07
07
07
0.9 to 1.1
18
07
07
07
0.9 to 1.1
10
10
07
07
0.9 to 1.1
13
10
07
07
0.9 to 1.1
16
10
07
07
0.9 to 1.1
18
10
07
07
0.9 to 1.1
13
13
07
07
0.9 to 1.1
16
13
07
07
0.9 to 1.1
18
13
07
07
0.9 to 1.1
16
16
07
07
0.9 to 1.1
18
16
07
07
0.9 to 1.1
10
10
10
07
0.9 to 1.1
13
10
10
07
0.9 to 1.1
16
10
10
07
0.9 to 1.1
18
10
10
07
0.9 to 1.1
13
13
10
07
0.9 to 1.1
16
13
10
07
0.9 to 1.1
18
13
10
07
0.9 to 1.1
16
16
10
07
0.9 to 1.1
18
16
10
07
0.9 to 1.1
13
13
13
07
0.9 to 1.1
16
13
13
07
0.9 to 1.1
18
13
13
07
0.9 to 1.1
16
16
13
07
0.9 to 1.1
10
10
10
10
0.9 to 1.1
13
10
10
10
0.9 to 1.1
16
10
10
10
0.9 to 1.1
18
10
10
10
0.9 to 1.1
13
13
10
10
0.9 to 1.1
16
13
10
10
0.9 to 1.1
18
13
10
10
0.9 to 1.1
13
13
13
10
0.9 to 1.1
16
13
13
10
0.9 to 1.1
13
13
13
13
0.9 to 1.1
16
16
10
10
0.9 to 1.1
– 43 –
Heat exchanger
Indoor
pipe temperature
fan
T1 (°C)
T2 (°C)
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
12 to 14
51 to 53
High
Compressor
Outdoor
revolution
fan
(rps)
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
61
MED
62
MED
62
MED
62

Hide quick links: