Configuring Alarm And Event - D-Link xStack DGS-3610 Series Configuration Manual

Hide thumbs Also See for xStack DGS-3610 Series:
Table of Contents

Advertisement

DGS-3610 Series Configuration Guide
Caution
Bucket-number: the control entry specifies the used data source and time interval. Each
sampling interval should be sampled once. The sampling results are saved. The
Bucket-number specifies the maximum number of sampling. When the maximum is reached
for the sampling records, the new one will overwrite the earliest one. The value range of
Bucket-number is 1-65535. Its default value is 10.
Interval: the time interval of sampling. Its default value is 1800 seconds, and its value range
is 1-3600.
26.2.3

Configuring Alarm and Event

One of these command can be used to configure the alarm form:
Command
DGS-3610(config)# rmon alarm number
variable interval {absolute | delta}
rising-threshold value [event-number]
falling-threshold value [event-number] [owner
ownername]
DGS-3610(config)# rmon event number [log]
[trap community] [description
description-string]
DGS-3610(config)# no rmon alarm number
DGS-3610(config)# no rmon event number
Number: the index of alarm form (event form) with the range of 1-65535.
Variable: the variable monitored by the alarm form. The variable must be an integer.
Interval: the time interval of sampling. Its range is 1-4294967295.
The keyword Absolute indicates each sampling value compared with the high and low limits.
The keyword Delta indicates the difference with previous sampling value compared with the
high and low limits.
Value defines the values of high limit and low limit.
Event-number: when the value exceeds the high or low limit, the event with the index of
Event-number will be triggered.
The keyword Log indicates the action triggered by the event is to record the event.
The current version of our product supports only the records of Ethernet.
The index value should be within 1-65535. At most 10 control entry can be
configured.
Chapter 26 Configuration of RMON
Function
Add an entry of history control.
Add an entry of Event.
Remove an alarm.
Remove an event.
26-3