Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MAGNETRON
Refer to page 4-27 for the procedure for ac-
cessing the magnetron.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
magnetron filament terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
filament terminals. The meter should in-
dicate less than 1 Ω.
Electrical Shock Hazard
Filament
Terminals
5-8
WAVEGUIDE THERMOSTAT
Refer to page 4-29 for the procedure for ac-
cessing the waveguide thermostat.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
thermostat connectors.
3.
Set the ohmmeter to the R x 100K scale.
4.
Touch the ohmmeter test leads to the
thermostat connector pins. The meter
should indicate a closed (0 Ω) circuit.