Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug microwave oven or disconnect
power.
2.
Remove the microwave oven from its
mounting location (see page 4-17 for the
procedure).
3.
Remove the cabinet from the microwave
oven (see page 4-18 for the procedure).
4.
CAUTION: Discharge the inverter board
(see step 4 on page 4-31 for the proce-
dure).
REMOVING THE RELAY BOARD
Relay Board
5.
Push out on the three outside tabs of the
relay board holder, and lift the relay board
out of the holder as far as the wires will
allow.
Relay Board
6.
Disconnect the wire connectors from the
relay board and remove the board from
the microwave oven. NOTE: The con-
nectors and their wire colors are shown
on the following page.
4-33
Relay Board
Holder Tabs