Whirlpool SPEEDCOOK GH6208 XR Technical Education page 60

Microwave oven with convection
Table of Contents

Advertisement

5.
To remove the magnetron thermistor:
a) Remove the screw from the magne-
tron thermistor and remove the therm-
istor from the magnetron.
b) Cut the wire tie and remove the mag-
netron thermistor wires from the wire
bundle.
c) Disconnect the magnetron thermis-
tor connector from relay control board
connector P74.
Control Board
Mag Thermistor
Connector P74
6.
To remove the magnetron:
a) Remove the magnetron thermistor
from the magnetron (see step 5a).
b) Remove the screw from the wire chan-
nel.
c) Remove the wires from the AC line fil-
ter board (this will allow enough slack
in the wires to remove them from the
wire channel later).
AC Line Filter
Magnetron
Thermistor
Screw
Wire Channel Screw
Board
d) Remove the three air duct screws, and
remove the air duct from the chassis.
NOTE: Remove the channel wires
from the air duct as you remove the
duct from the unit.
Air Duct
e) CAUTION: Discharge the inverter
board (see step 4 on page 4-31 for the
procedure).
f) Disconnect the two filament wires from
the magnetron terminals.
g) Remove the four T20 torx screws from
the magnetron, and remove the mag-
netron from the microwave oven.
4-28
Air Duct
Screws
Magnetron
Screws
Magnetron
Filament Wires

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speedcook gh7208 xr

Table of Contents