Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
TURNTABLE MOTOR
Refer to page 4-5 for the procedure for access-
ing the turntable motor.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
turntable motor terminals.
3.
Set the ohmmeter to the R x 10K scale.
4.
Touch the ohmmeter test leads to the
motor terminals. The meter should indi-
cate 2.2 K ±0.5 KΩ.
Electrical Shock Hazard
LINE FUSE
Refer to page 4-7 for the procedure for access-
ing the line fuse.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the fuse
holder terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
fuse holder terminals. The meter should
indicate a closed (0 Ω) circuit.