Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DOOR INTERLOCK SWITCHES
Refer to page 4-16 for the procedure for ac-
cessing the door interlock switches.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wires from the interlock
switch terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the ter-
minals of the primary or secondary switch
(normally-open). The meter should indi-
cate an open (infinite) circuit.
5.
Touch the ohmmeter test leads to the
terminals of the monitor switch (normal-
ly-closed). The meter should indicate a
closed (0 Ω) circuit.
NOTE: Pressing the actuator button on the
switches should result in opposite readings
(normally-open should read closed, and nor-
mally-closed should read open).
Electrical Shock Hazard
FC THERMOSTAT
Refer to page 4-19 for the procedure for ac-
cessing the FC thermostat.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
thermostat terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
thermostat terminals. The meter should
indicate a closed (0 Ω) circuit.
5-3