Processors - Fujitsu PRIMERGY TX2540 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX2540 M1:
Table of Contents

Advertisement

Basic software procedures
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
The memory counter can be reset using the meclear utility which is part of the
ServerView agents for Linux. For further details, please refer to the meclear
manual pages.
Ê Log in as root.
Ê Enter the command below, followed by [ENTER]:
/usr/sbin/meclear
I
meclear (Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it
has been replaced.
Ê Select the number of a memory module with a status other than "OK" or
"Not available".
Ê Repeat the step above until all memory modules show the "OK" status.
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2

Processors

ServerView Operations Manager may report a defective processor in case of a
critical error.
I
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start > (All) Programs > Fujitsu > ServerView Suite > Agents >
Maintenance Tools
– Windows Server 2012 and above:
Start > Apps > Fujitsu > Maintenance Tools
94
Upgrade and Maintenance Manual
TX2540 M1

Advertisement

Table of Contents
loading