Removing A Slimline Odd Or Lsd; Preliminary Steps; Removing The Multibay Box - Fujitsu PRIMERGY TX2540 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX2540 M1:
Table of Contents

Advertisement

Accessible drives and LSD

12.5.2 Removing a slimline ODD or LSD

Upgrade and Repair Unit
(URU)
Tools: Phillips PH2 / (+) No. 2 screw driver

12.5.2.1 Preliminary steps

"Removing backup and optical disk media" on page 80
Ê
"Shutting down the server" on page 48
Ê
"Disconnecting the server from the mains" on page 48
Ê
"Getting access to the component" on page 49
Ê
I
The front cover only needs to be removed in order to remove or install
accessible drive dummy covers. If the Multibay will be reinstalled after
removing the slimline ODD or LSD module, the front cover can
remain installed.
"Removing the system fan holder" on page 74
Ê

12.5.2.2 Removing the Multibay box

Ê Remove all cables from the slimline ODD.
Ê Remove the LSD cable from system board connector SMB 1.
Ê Press out on the locking latch to disengage the accessible drive locking bar
(see figure 214).
Ê Fold up the accessible drive locking bar.
316
Upgrade and Maintenance Manual
Hardware: 10 minutes
TX2540 M1

Advertisement

Table of Contents
loading

Table of Contents