4F-12 ANTILOCK BRAKE SYSTEM
Defect Code
Rear / right OUTLET Valve
20
Function and Response of The
21
Valve
Function and Response of The
22
Valve
Motor Relay / Circulation Pump
24
Stop Lamp Switch
27
Application
Description
(When connector is removed)
Replace the hydraulic modulator.
Check each valve by using SCANER's solenoid valve
overriding function.
Check connection of connector and terminals in the
ECU hydraulic modulator.
Check terminals for open or short.
(When connector is removed)
Replace the hydraulic modulator.
Check solenoid internal resistance of the prime(ASV)
valve and pilot valve(USV) : 8.04 - 9.04 W
Check each valve by using SCANER's solenoid valve
overriding function.
Check connection of connector and terminals in the
ECU and hydraulic modulator.
Check terminals for open or short.
(When connector is removed)
Replace the hydraulic modulator.
Check solenoid internal resistance of the prime(ASV)
valve and pilot valve(USV) : 8.04 - 9.04 W
Check each valve by using SCANER's solenoid valve
overriding function.
Check connection of connector and terminals in the
ECU and hydraulic modulator.
Check terminals for open or short.
(When connector is removed)
Replace the hydraulic modulator.
Check each valve by using SCANER's pump motor
overriding function.
Check resistance between pump motor ground ter-
minal and battery negative terminal : total resistance
should be less than 15 mW.
Check body ground location.
Check relay supply voltage : IGN on : 11 - 14 V
Relay coil internal resistance : 70 - 80 W
Replace the hydraulic modulator.
Check by using SCANER's stop lamp switch diagnos-
ing function from sensor value output function.
Check connection of ECU connector side stop lamp
switch terminal.
Check resistance of the stop lamp switch.
- Each end resistance value of the switch