##670 [TX]
In V.8 late start, the V.8 ability was detected in DIS
from the other party and, in response, CI was
transmitted; however, the procedure failed to advance,
causing a T1 time-over condition
Cause:
CI was transmitted, but the other party failed to receive it correctly
and disconnect the line.
Remedy:
(1) Increase the transmission level so that the other party may
receive CI correctly.
(2) Prohibit the V.8/V.34 procedure.
Cause:
ANSam or DIS from the other party cannot be received correctly.
Remedy:
(1) Ask the operator of the other party to increase the transmission
level so that the signal may be received correctly.
(2) Prohibit the V.8/V.34 procedure.
##671 [RX]
In V.8 call arrives, the procedure fails to advance to
phase 2 after CM detection, causing a T1 time-over
condition
Cause:
In phase 1, the other party cannot receive the signal correctly and
disconnect the line.
Remedy:
(1) Increase the transmission level so that the other party may
receive the signal correctly.
(2) Prohibit the V.8/V.34 procedure.
Cause:
In phase 1, the signal from the other party cannot be received
correctly.
Remedy:
(1) Ask the operator of the other party to increase the transmission
level so that the signal may be received correctly.
(2) Prohibit the V.8/V.34 procedure.
##672 [TX]
In V.34 transmission, the procedure fails to move from
phase 2 to phase 3 and later, causing a T1 time-over
condition
Cause:
In phase 2, the other party cannot receive the signal correctly, and
disconnect the line.
T-14-58