3) Close the cartridge cover.
4) Disconnect the connector [2], and detach the
control panel [1].
To prevent damage to the flexible cable, be sure to lift
the
control
panel
disconnecting the connector [2].
[2]
F-8-54
MEMO:
To mount the control panel, turn it over as shown in
below figure, and connect the connector [1]; then, turn
back over [2] the control panel to facilitate the work.
F-8-55
8.4.4.7
Removing
Copyboard Glass
1) Open the ADF (copyboard cover).
slightly
as
shown
[1]
[2]
[1]
the
0006-3628
2) Remove the 2 screws [1], and detach the copyboard
glass retainer [2].
3) Remove the copyboard glass [3].
when
8.4.4.8 Removing the Fixing
Assembly
1) Remove the cover [1].
2) Slide the reader unit so that the hole in the reader
unit and the hole in the top plate match.
[1]
[3]
[2]
F-8-56
[1]
F-8-57