3Com 3CRWEASYA73 User Manual page 263

3com outdoor 11a building to building bridge and 11bg access point
Hide thumbs Also See for 3CRWEASYA73:
Table of Contents

Advertisement

host does not respond or is unreachable) exceeds the limit set by the
link-integrity ping-fail-retry command, the link is determined as lost.
Example
Outdoor 11a Building to Building (config)#link-integrity ping-detect
Outdoor 11a Building to Building (config)#
link-integrity ping-host
This command configures the link host name or IP address. Use the no form to
remove the host setting.
Syntax
link-integrity ping-host <host_name | ip_address>
no link-integrity ping-host
• host_name - Alias of the host.
• ip_address - IP address of the host.
Default Setting
None
Command Mode
Global Configuration
Example
Outdoor 11a Building to Building (config)#link-integrity ping-host
192.254.2.10
Outdoor 11a Building to Building (config)#
link-integrity ping-interval
This command configures the time between each Ping sent to the link host.
Syntax
link-integrity ping-interval <interval>
interval - The time between Pings. (Range: 5 - 60 seconds)
Default Setting
30 seconds
Command Mode
Global Configuration
6-151
Using the Command Line Interface